User's Manual

17
Loner 900 will continue all of the alarms until one of the following occurs:
Loner 900 automatically shuts down with a depleted battery; or Loner 900 is plugged in
for charging.
Loner 900 sends a Loner 900 Powered O by Low Battery message to the Loner
Background Services before nally powering o.
If Loner 900 powers o with low battery, it will annunciate with a three second beep,
vibrate and indicator light array ash.
Troubleshooting
Subtext goes here introducing the following section.
SubHead goes here. Required for table of contents.
Paragraph text goes here introducing the following chart.
Symptom Cause Solutions
Green power
light is
blinking
Loner is not connected
to the Loner Portal
Ensure Bridge is turned On (It may
take up to 2 minutes after power-on
to connect.); Ensure Bridge has line-
of-sight view to the sky to connect
our satellite.
Lots of false
fall alarms
Loners fall detect algo-
rithm is being tripped
Desensitize the fall detect settings in
the portal. You can raise the thresh-
old from the default 3.5 to reduce
false alarms.
Too many No-
motion alarms
The No-motion alarm can be made
less sensitive. The time window can
also be changed through the Loner
Portal.