Instructions / Assembly

9
Lighting the Griddle
Do not lean over the griddle while lighting.
Read instructions before lighting.
1. Read all instructions before lighting.
2. Push the control knob in to start gas owing.
3. Turn the control knob counter-clockwise to
activate the starter.
4. Adjust the temperature to desired level.
5. If ignition does not occur, turn gas o by turning the knob
clockwise and repeat lighting instructions.
Oil Drip Tray
Check the oil drip tray often and clean out after each use.
Ignition Needle Placement
The ignition needle should be 3-7 millimeters from the burner
tube to create the proper spark. The ignition needle should not
touch the burner tube.
Disconnecting the LP Bottle
Make sure your griddle is o and cool. Disconnect the
regulator from the gas line by unscrewing the collar, then
unscrew the LP bottle from the regulator.
Match Lighting Instructions
Do not lean over the Griddle while lighting. Make sure there
are no gas leaks.
1. Ensure the control knob is in the “OFF” position.
2. Remove the griddle top.
3. Light an 11” long match, then place the match on the right
or left side of the burner.
4. Push in and turn the control knob to the HIGH position. Be
sure burner lights and stays lit.
Control Knobs
Oil Drip Tray
CUSTOMER NOTICE: To perform a leak test of your gas
connections, mix a 50/50 solution of soap and water and
brush around regulator and other gas connections. If growing
bubbles appear, there is a leak. Re-tighten connections. If leaks
cannot be stopped do not try to repair. Call for replacement
parts at (435) 252-3030.
3-7 mm