Auto User's manual
BLAUBERG Company is happy to offer your attention a new generation product, the BLAUBERG Auto fan. The solid team of high-qualified professionals with many years of working experience, technological innovations in design and production, high-quality components and materials from the top worldwide producers have become the precondition for the best fan in its class.
BASIC CHARACTERISTICS The fan designations, parameters, outer view, overall and connecting dimensions are shown in tables 1, 2, 3 and in fig. 1 and 2. Table 1 Noise level, 3m [dBA] Max.
Fig. 1 1 - cover; 2 - casing; 3 - motor; 4 - impeller. 4 3 2 1 Table 3 Dimensions [mm] a b1 b2 b3 c d e Weight [kg] Auto 100 166 150 150 150 90 100 30 0,56 Auto 125 186 128 173 174 98 125 33 0,73 Auto 150 210 150 195 196 115 150 34 0,9 Model Fig.
OPERATION RULES The fan is rated for connection to 220...240 V / 50 Hz power mains and is designed for continuous operation always connected to power mains. The air motion direction in the system must match the pointer on the fan casing. The fan is rated for operation at ambient temperature from +1 °C up to +45 °C. The unit is rated as a Class II electrical appliance.
The product is not allowed for use by children and persons with reduced physical, mental or sensory capacities, without proper practical experience or expertise, unless they are controlled or instructed on the product operation by the person(s) responsible for their safety. Supervise the children and do not let them play with the product. Take steps to prevent ingress of smoke, carbon monoxide and other combustion products into the room through open chimney flues or other fire-protection devices.
MOUNTING AND SETUP The fan is designed for ceiling or wall mounting to extract air into a ventilation shaft or matching air duct of respective diameter (fig. 3-7). The fan mounting sequence is shown in fig. 8-9. The fan wiring diagrams are shown in fig. 10-16. Fig. 3 Fig. 5 7 Fig.
Fig. 6 Fig. 8 Fig. 7 Fig.
WIRING DIAGRAMS AND FAN OPERATING LOGIC Auto _____ QF N Fig. 10 Fan does not run S N L L QF N S N L L Switch is closed Fan runs Switch is opened S S - external switch QF - automatic circuit breaker Auto _____S Fig.
Fig. 12 Auto _____T QF N N S Fan does not run LT L L Switch is closed QF N N S LT L L - Fan runs T 2min Switch is opened + 30min Turn-off delay timer starts (2 to 30 min) S S - external switch QF - automatic circuit breaker Fig.
Fig.
Fig.
Fig.16 Auto _____IR Fan does not run QF N N L L - T 2min Motion is detected Fun runs + No motion detected 30min Turn-off delay timer starts (2 to 30 min) QF - automatic circuit breaker Fig. 17 Warning! The timer circuit is under mains voltage! Disconnect the fan from power mains prior to any adjustment operations. The fan delivery set includes a specially designed plastic screwdriver for fan settings adjustments. Use the screwdriver to alter the turnoff delay time threshold.
MAINTENANCE Any servicing and maintenance operations of the fan are allowed after it is disconnected from power mains only. Maintenance means regular cleaning of the fan surfaces from dirt and dust. To clean the fan, wipe its surfaces with a cloth wetted in a mild soap solution, then wipe the surfaces dry.
MANUFACTURER'S WARRANTY The fan complies with the requirements according to the EU norms and directives, to the relevant EU-Low Voltage Equipment Directives, EU-Directives on Electromagnetic Compatibility.
AUTO 100 125 150 S T H ST SH IR Model is recognized as serviceable.