The self-contained LP system appliance is design certified to be used with a standard 20 lb., 12 1/4" diameter;
18"
high cylinder with right handed connection threads and this is the maximum size LP tank to be used. The
cylinder
must be marked in accordance with the latest U.S. Department of Transportation specifications for LP
gas cylinders.
(DOT. CFR49 or National Standards of Canada CAN/CSA-B359 Cylinders, Spheres and Tubes for
the
Transportation of Dangerous Goods) a Propane Tank with an ODP) Overfill Prevention Device) must be used
at all
times.
IMPORTANT: Never connect the appliance to an unregulated gas supply.
If there are local codes that apply to outdoor grills, you will have to confirm them with the local authority.
Installation must conform with local codes or in the absence of local codes, to the National Fuel Gas Code, ANSI
Z223.1/NFPA 54 and Natural Gas Installation Code, CSA B149.1. All Natural Gas installations must conform to
local codes or in the absence of local codes
the national fuel gas code, ANSIZ2223.1a-
1998.
If there are local codes that apply to outdoor burners, you will have to conform to them. Installation must conform
with local codes or, in the absence of local codes, with Propane Installation Code, CSA B149.1, or Propane
Storage and Handling Code, B149.2 as applicable.
Installation in Canada must be in accordance with the standard CAN/CGA-
B149.2.
A licensed contractor or local gas company representative must perform all gas connections.
Ensure that the service supplying the appliance is fitted with a shut off valve conveniently positioned near the
appliance and giving ease of access.
The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during
any
pressure testing of that system.
GAS LEAK WARNINGS
Finding and/or fixing a gas leak is NOT a “DO-IT-YOURSELF” procedure ONLY USE A
PROFESSIONAL.
NEVER USE THE GRILL WITHOUT FIRST LEAK TESTING THE GAS CONNECTIONS INCLUDING
ALL OF THE VALVES, FITTINGS, LINES ETC. (ALL GAS CONNECTIONS SHOULD BE CHECKED)