WARNING: AFTER STARTING FIRMWARE UPGRADE, DO NOT POWER DOWN
KONTROL 6 UNTIL THE UPGRADE FINISHES!!! UNPLUG ALL FIXTURES FROM
KONTROL 6 PRIOR TO PROCEEDING.
1. Turn the unit off.
2. With the unit off, press and hold the <EDIT/REC> & <LEFT> but-
tons.
3. Continue to hold the button combination until KONTROL 6’s LED dis-
play shows “UP--.”
4. Release the button combination, then press any button to proceed
with the upgrade.
5. Once upgrade is complete, KONTROL 6 will display the “OK” message
(ot) as indicated above.