User manual

Page 13
The Puck™ V12 Manual Rev. A © 2013 Blizzard Lighting, LLC
2.) ARC.1 - Architectural Mode 1 (RGB, 3-Ch.)
Channel Value What It Does
1 000 <--> 255 Red Intensity (0% <--> 100%)
2 000 <--> 255 Green Intensity (0% <--> 100%)
3 000 <--> 255 Blue Intensity (0% <--> 100%)
3.) AR1.d - Architectural Mode #1 w/dimming (RGB, 4-Ch.)
Channel Value What It Does
1 000 <--> 255 Master Dimmer (0% <--> 100%)
2 000 <--> 255 Red Intensity (0% <--> 100%)
3 000 <--> 255 Green Intensity (0% <--> 100%)
4 000 <--> 255 Blue Intensity (0% <--> 100%)
4.) ARC.2 - Architectural Mode 2 (RGBAW 5-Ch.)
Channel Value What It Does
1 000 <--> 255 Red Intensity (0% <--> 100%)
2 000 <--> 255 Green Intensity (0% <--> 100%)
3 000 <--> 255 Blue Intensity (0% <--> 100%)
4 000 <--> 255 Amber Intensity (0% <--> 100%)
5 000 <--> 255 White Intensity (0% <--> 100%)
5.) AR2.d - Architectural Mode #2 w/dimming (RGBAW, 6-Ch.)
Channel Value What It Does
1 000 <--> 255 Master Dimmer (0% <--> 100%)
2 000 <--> 255 Red Intensity (0% <--> 100%)
3 000 <--> 255 Green Intensity (0% <--> 100%)
4 000 <--> 255 Blue Intensity (0% <--> 100%)
5 000 <--> 255 Amber Intensity (0% <--> 100%)
6 000 <--> 255 White Intensity (0% <--> 100%)