ToughPAR Quadra Manual Rev. A      Copyright (c) 2012 Blizzard Lighting, LLC
3. SETUP
Fuse Replacement
CAUTION! The ToughPAR™ Quadra utilizes a high-output switch-
mode power supply with an internal fuse. Under normal operating 
conditions, the fuse should not require replacement. The fuse is fi eld 
replaceable, however it is an advanced procedure suited to qualifi ed 
individuals. Should your ToughPAR™ fuse require replacement, please 
contact Blizzard Lighting for instructions, or to return your unit for 
service.
Connecting A Bunch of ToughPAR™ Quadra Fixtures
You will need a serial data link to run light shows using a DMX-512 
controller or to run shows on two or more fi xtures set to sync in mas-
ter/slave operating mode. The combined number of channels required 
by all the fi xtures on a serial data link determines the number of fi x-
tures the data link can support.
Fixtures on a serial data link must be daisy chained in one single line. 
Also, connecting more than 32 fi xtures on one serial data link without 
the use of a DMX optically-isolated splitter may result in deterioration 
of the digital DMX signal.
The maximum recommended cable-run distance is 500 meters (1640 
ft). The maximum recommended number of fi xtures on a serial data 
link is 32 fi xtures.
Data/DMX Cabling
To link fi xtures together you’ll need data cables. You should use data-
grade cables that can carry a high quality signal and are less prone to 
electromagnetic interference.
For instance, Belden© 9841 meets the specifi cations for EIA RS-485 
applications. Standard microphone cables will “probably” be OK, but 
note that they cannot transmit DMX data as reliably over long distanc-
es. In any event, the cable should have the following characteristics:
  2-conductor twisted pair plus a shield
  Maximum capacitance between conductors – 30 pF/ft.
  Maximum capacitance between conductor & shield – 55 pF/ft.
  Maximum resistance of 20 ohms / 1000 ft.
  Nominal impedance 100 – 140 ohms