BCT and BLCT Series Combi Ovens Manual

4
Installation
Description of the Combi-Oven/Steamer
ABOUT THE OVEN/STEAMER
Blodgett Combis are quality produced using high-grade
stainless steel with rst class workmanship.
The multiple speed fan, which is guarded against acci-
dental nger contact, is driven by a quiet and powerful
motor. The condenser draws out excess steam from the
appliance. Condensation and waste water, which result
during steaming and cleaning, are continuously drained.
The use of high quality insulation impedes excessive heat
radiation and saves energy.
Fresh steam enters the oven cavity without pressure and
circulates at high speed. This process enables quick and
gentle cooking and ensures high quality food while pro-
viding convenient working methods. The steam generator
is completely automatic and protected from running dry.
OVEN/STEAMER OPERATION
The practical oven door, with a viewing window, has a
wide swing radius and handle which can be operated eas-
ily, even with wet or greasy hands.
Ease of operation is guaranteed through the simple to use
control. With graphical symbols and storage for 50 prod-
uct recipes the BCT/BLCT is easy for even inexperienced
kitchen staff to operate.
Cleaning is kept to a minimum thanks to the automatic
Combi Wash system.
PLUMBING SPECIFICATIONS
WATER
Water pressure 36.26 PSI (250 kPa, 2.5 bar) during Combi Wash
21.76 PSI (150 kPa, 1.5 bar) when Combi Wash is not active
40(min)-50(max) PSI supply pressure
Water connection 3/4” garden hose cold water
Water quality requirements TDS: 40-125 ppm
Hardness: 35-100 ppm
Chlorides: <25 ppm
Silica: <13 ppm
Chlorine: < 0.2 ppm
Chloramine: < 0.2 ppm
pH: 7.0-8.5
DRAINAGE
Drain type Atmospheric Vented Drain
Drain connection 2.00” (50.8mm) Copper
1.57” (40mm) Copper - mini combi ovens
Maximum water drain temperature 140ºF (60ºC)
RATINGS - GAS OVENS
Model Gas Type Input Voltage Phase Amps
BLCT-61G Natural 58,000 BTU 115 1 9
Propane 58,000 BTU 115 1 9
BLCT-101G Natural 87,000 BTU 115 1 9
Propane 87,000 BTU 115 1 9
BLCT-102G Natural 95,500 BTU 115 1 9
Propane 95,500 BTU 115 1 9
BLCT-62G Natural 81,800 BTU 115 1 9
Propane 81,800 BTU 115 1 9
BLCT-202G Natural 190,000 BTU 115 1 17
Propane 190,000 BTU 115 1 17