- BLODGETT COMBI OPERATIONS INSTRUCTION BCX 14G BCX 14E BX 14G BX 14E CNVX 14G CNVX 14E

Entretien
69
Communications (Unités BCXĆ14 et BXĆ14 seulement)
Le four est équipé d'un port de communication séĆ
riel RSĆ232 situé à l'intérieur du panneau de comĆ
mande. Un ordinateur portable peut être utilisé
pour visualiser des informations concernant cerĆ
tains paramètres de l'appareil, y compris son hisĆ
torique de détartrage. Une vue d'écran typique est
montrée ciĆdessous.
Software (c) 2002 Blodgett
Blodgett Combi BC-2 Control
ROM Saved Data
===========================
Version -> 3
Model -> 0
Startup Date-> 25
Startup Month -> 6
Startup Year -> 2
Low Volt -> 37
High Volt -> 80
Steam Time(sec) -> 16384
SD Time(sec) -> 457
CNV Time(sec) -> 239087
Combi Time(sec)-> 71870
Heat DMD events -> 0378956
Current time -> 11h : 22m : 10s
Current date -> 26 day 6 month 2 year
Total deliming events -> 3
Steam has been run -> 21 hour(s) 52 min(s) 8 sec(s) since last deliming.
Next deliming in approximately 3 hour(s) of Steam Generator run time.
Deliming interval is 24 hour(s) of Steam Generator run time.
Deliming History
=====================================
Last address 5 and state 0
Event no. 1 on 25 day 5 month 2 year
Event no. 2 on 23 day 6 month 2 year
Event no. 3 on 21 day 7 month 2 year
Event no. 4 on 0 day 0 month 0 year
Event no. 5 on 0 day 0 month 0 year
Explanation of output
Version ć Software version.
Model ć 1= Gas oven, 0 = Electric oven.
Startup Date, Month, Year ć Date oven was started up.
Low Volt,High Volt ć Power supply fluctuations.
Steam Time - Time in second's oven has used Steam Mode.
SD Time - Time in second's oven has used in On Demand Steam mode.
CNV Time - Time in second's oven has used Hot Air Mode.
Combi Time - Time in second's oven has used in Combi Mode.
Heat DMD events ć Total number of heat demand events.
Current time, Current date - Current date and time.
Total deliming events - Total number of times oven has been delimed.
Steam has been run -> - How long steam generator has been run since last deliming.
Next deliming.. ć Approximately next time steam generator will need a deliming.
Deliming interval ..ć Hours the steam generator will run between deliming events.
Deliming History - The last 52 events will be printed out. If an event has not occurred, a 0 will be
used. Last address and state are used to record the last deliming state in
case of power fail during the process. Normally, state should be 0.
Figure 51