The Steamers are designed to operate smoothly and efficiently when properly maintained. However, the following is a list of things
to check if there is a problem. Wiring diagrams are furnished inside the service panel.
SYMPTOM WHAT TO CHECK
Timer control will not operate. a. Is the electrical supply turned on?
b. Is the ON/OFF switch in the base cabinet turned on?
c. Is the green light in the ON/OFF switch lit?
d. Are any fuses blown?
No steam to cavities. a. Is steam supply turned on?
b. Is the door closed? (Doors must be closed before steam will enter the
cavity).
Door leaking steam or water. a. Are the drain holes at the rear of the cavity blocked?
b. Does the door gasket need replacement?
c. Is the door latch in need of adjustment? (See the Maintenance section).
d. Is the unit level?
Excessive steam coming from the vent
pipe.
a. Is the water supply turned on?
b. Is the condenser hose kinked or obstructed?
c. Is the condenser spray solenoid working?