- BLODGETT CONVECTION OVEN INSTALLATION -- OPERATION -- MAINTENANCE KCO-25E
Installation
7
Utility Connections
THE INSTALLATION INSTRUCTIONS CON-
TAINED HEREIN ARE FOR THE USE OF QUALI-
FIED INSTALLATION AND SERVICE PERSONNEL
ONLY. INST ALLATION OR SERVICE B Y OTHER
THAN QUALIFIED PERSONNEL MAY RESULT IN
DAMAGE TO THE OVEN AND/OR INJURY TO
THE OPERATOR.
Qualified installation personnel are individuals, a
firm, a corporation, or a company which either in
person or through a representative are engaged
in, and responsible for:
D the installation of electrical wiring from the elec-
tric meter, main control box or service outlet to
the electric appliance.
Qualified installation personnel must be experi-
enced in such work, familiar with all precautions
required, and have complied with all requirements
of state or local authorities having jurisdiction.
U.S. and Canadian installations
All ovens, when installed, must be electrically
grounded in accordance with local codes, or in the
absence of local codes, w ith the National Electrical
Code, ANSI/NFPA 70 ---Latest Edition and/or Cana-
dian National Electric Code C22.2 as applicable.
The ventilation of this oven should be in accor-
dance with local codes. In the absence of local
codes, refer to the National ventilation code titled,
“Standard for the Installation of Equipment for the
Removal of Smoke and Grease Laden Vapors from
Commerc ia l Cooking Equipment”, NFP A-96-Latest
Edition.
General export installations
Installation must conform with Local and National
installation standards. Local installation codes
and/or requirements may vary. If you have any
questions regarding the proper installation and/or
operation of your Blodgett oven, please contact
your local distributor. If you do not have a local dis -
tributor, please call the Blodgett Oven Company at
0011-802-860-3700.
ELECTRICAL CONNECTION
U.S and Canadian installations
This unit is supplied with a power cord and 6-20P
NEMA plug (3 prong grounding 250 volt). It is in-
tended for use with a 6 -20R NEMA receptacle.
WARNING!!
This appliance is equipped with three
pronggroundingtypeplugforyour
protection against shock hazard and
should be plugged directl y into a properly
grounded three prong receptacle. DO
NOT cut or remove the grounding prong
from this plug.
General export installations
Before making any utility connections to this oven,
check the rating plate attached to the back of the
oven to be sure the voltage, phase and KW rating
are compatible with the electrical services sup-
pliedfortheoven.Seethetableonpage2forelec-
trical specifications.
THE BL ODGETT OVEN COMPANY CANNOT AS-
SUME RESPONSIBILITY FOR LOSS OR DAMAGE
SUFFERED AS A RESULT OF IMPROPER INSTAL-
LA TION.