Manual

OM-SC-E 9
Operation
NOTE: Before the steamer can be operated as described in this section, the pilot
burner flame must be established. For details see the Initial Start-Up section and the
Automatic Operation of Pilot on previous page.
A. Controls
Operator controls are on the front right of the unit. The control panel on new
models has the following touch pads and indicator lights:
• TheON/OFFtouchpadgetsthesteamerreadyforuse,orshutsitoff.
• TheREADYindicatorlightshowsthatthesteamgeneratorisatstandby
temperature and the cavity is hot enough to begin steaming.
• TheDELIMEindicatorlightislitwhentheunitisoperatinginthecleaning
mode.
• TheSERVICEindicatorlightshowswhenthewaterlevelprobeshavestopped
working, and need to be cleaned (normally an indication of lime deposits).
When one probe is not working, the DELIME light flashes briefly every few
seconds. If both probes fail the SERVICE light will come on continuously and
the beeper will sound.
• TheHITEMPindicatorlightcomesonwhenthesteamgeneratoristoohot.
The unit will automatically shut off, and cannot be turned on again until the
steam generator cools and the HI TEMP indicator light goes out.
• TheTIMINGindicatorlightstaysonwhenthetimerisrunning.
• TheCLEANtouchpadisusedtostarttheautomatic50minutecleaningcycle.
The timer is used in three ways:
1. In the OFF position the steam generator stays at a low boil or “holding”
temperature.
2. When a cook time is set, the unit steams until the timer runs down to OFF.
Steaming stops, the DONE light (a red light on older models) comes on and
a beeper sounds.
3. With the timer turned to the ON position, the unit steams continuously. The
green light stays lit. The steamer will not time down.
WARNING
WHEN YOU OPEN THE DOOR, STAY AWAY
FROM THE STEAM COMING OUT OF THE
UNIT. THE STEAM CAN CAUSE BURNS.
WARNING
ALL POTENTIAL USERS OF THE EQUIPMENT
SHOULD BE TRAINED IN SAFE AND CORRECT
OPERATING PROCEDURES.
NO ATTEMPT SHOULD BE MADE TO
OPERATE THIS EQUIPMENT DURING
A POWER FAILURE.
Power
ON/OFF
Button
Power
Indicator
Light
Service
Indicator
Light
Clean
Button
Steamer
Timer
Ready
Indicator
Light
Delime
Indicator
Light
Hi Temp
Indicator
Light