User Manual and Installation Guide

12 / EN
Dryer / User Manual
Ventilation Requirements
Closet door must have 2 openings, one
located 3.2 inches (8 cm) from bottom of
door having a minimum area of 16 sq.
inches (103 cm2) and the other one located
3 inches (7.5 cm) from top of door having a
minimum area of 46 sq. inches (294 cm2).
3.5 Use on top of a washer
•A stacking-kit (Part no: 297 956 0100)
should be used between the washer and
dryer for use on top of a washer. The
stacking-kit should be installed by the
Authorized Service provider.
3.4 Minimum Installation
Clearances
Alcove or
Built-under
Closet
Sides 0.59 in. (15 mm) 0.59 in. (15 mm)
Top 2.42 in. (61.5 mm) 2.42 in. (61.5 mm)
Rear 0.59 in. (15 mm) 0.59 in. (15 mm)
Front 0.2 in. (5 mm) 0.2 in. (5 mm)
33 ¾"
(856,5 mm)
23
(59 5 mm)
22
(583 mm)
7
16
"
/
15
/
16
"
90
0
90
0
36.14
(918 mm)
min.
23.7
603 mm
min.
24.6
(625 mm)
min.