642 BLOOMFIELD INDUSTRIES 10 Sunnen Drive St. Louis, MO 63143 telephone: 314-678-6336 fax: 314-781-2714 www.wellsbloomfield.com OWNERS MANUAL for E. B. C.™ Electronic Brew Control ™ AIRPOT AND THERMAL SERVER COFFEE BREWERS MODELS 1080 1082 1082XL 1086 1088 Includes: Installation Use & Care Servicing Instructions Model 1082 Brewer with optional 7752 Airpot p/n 2M-75872 Rev. H E.B.C.™ brewers are protected under U. S. Patent # 5, 704,275 Other U. S. and Canadian patents pending.
WARRANTY STATEMENT It also does not apply if the serial nameplate has been removed or unauthorized service personnel perform service. The prices charged by Bloomfield Industries for its products are based upon the limitations in this warranty. Seller’s obligation under this warranty is limited to the repair of defects without charge by a Bloomfield Authorized Service Agency or one of its sub-agencies. This service will be provided on customer’s premises for non-portable models.
TABLE OF CONTENTS WARRANTY STATEMENT SPECIFICATIONS FEATURES & OPERATING CONTROLS PRECAUTIONS & GENERAL INFORMATION AGENCY LISTING INFORMATION INSTALLATION INSTRUCTIONS OPERATION BREWING COFFEE CLEANING INSTRUCTIONS TROUBLESHOOTING SUGGESTIONS SERVICING INSTRUCTIONS Deliming Instructions EXPLODED VIEWS & PARTS LISTS WIRING DIAGRAMS xi 1 2 3 3 4 6 10 11 12 14 20 22 - 25 26 - 27 Thank You for purchasing this Wells Bloomfield appliance.
IL1726 Fig.
PRECAUTIONS AND GENERAL INFORMATION WARNING: ELECTRIC SHOCK HAZARD All servicing requiring access to non-insulated components must be performed by qualified service personnel. Do not open any access panels which require the use of tools. Failure to heed this warning can result in electrical shock. WARNING: INJURY HAZARD All installation procedures must be performed by qualified personnel with full knowledge of all applicable electrical and plumbing codes.
INSTALLATION INSTRUCTIONS READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION CAUTION: EQUIPMENT DAMAGE DO NOT plug in or energize this appliance until all Installation Instructions are read and followed. Damage to the Brewer will occur if these instructions are not followed. CAUTION: UNSTABLE EQUIPMENT HAZARD It is very important for safety and for proper operation that the brewer is level and stable when standing in its final operating position.
INSTALLATION INSTRUCTIONS (continued) NSF requires that the brewer be able to be moved for cleaning underneath. A flex line or loops of copper tubing will satisfy this requirement. See Figure 2 below. NOTE: This equipment must be installed to comply with applicable federal, state and local plumbing codes and ordinances. WARNING: SHOCK HAZARD IL1615 Fig. 2 Water Supply Installation In some areas, local codes require a backflow preventer (check valve) to be installed on the inlet water line.
OPERATION SOLENOID TIMER (WATER VOLUME) (SECONDS) BREW SIGNAL TIMER: -BREW LIGHT END OF BREW BEEPER (MINUTES) IL1727 Fig. 4 Brewer Operation Diagram A. START-UP For initial start-up, or if the brewer has not been used for an extended period of time: • Be sure spray disk and brew gasket are properly installed in the brew head. • Be sure the water supply is properly connected and the water supply valve is turned ON.
OPERATION (continued) WATER HEATER Water temperature is sensed by an electronic water temperature probe inserted into the water tank. This temperature signal is fed to the controller. The setpoint temperature is adjustable. The controller sends a command signal to the power board based upon a comparison between the setpoint temperature and actual temperature. See page 15. The power board energizes the heating elements based on the command signal from the controller.
OPERATION (continued) IMPORTANT: DO NOT energize this brewer until the water tank has been filled. Dry firing will damage heating elements. See page 6. ELECTRONIC FEATURES Energizing the Brewer When electric power is applied to the unit, all the lights will flash four times and four beeps will sound. The unit will be off. Press the ON/OFF key. Four beeps will sound and all lights will flash once. The POWER indicator will remain on.
OPERATION (continued) Quality Timer Coffee looses its freshness as it sits on a warmer. The Quality Timer flashes the warmer lights 30 minutes after the last brew to remind you that the coffee is nearing the end of its useful life. After Hours™ Operation During normal operation, the controller will maintain the precise brewing temperature.
BREWING COFFEE BURN HAZARD Exposed surfaces of the brewer, brew chamber and airpot or server may be HOT to the touch, and can cause serious burns. CAUTION: BURN HAZARD To avoid splashing or overflowing hot liquids, ALWAYS place an empty airpot or server under the brew chamber before starting the brew cycle. Failure to comply can cause serious burns. CAUTION: BURN HAZARD After a brew cycle, brew chamber contents are HOT. Remove the brew chamber and dispose of used grounds with care.
CLEANING INSTRUCTIONS CAUTION: PROCEDURE: Clean Coffee Brewer BURN HAZARD PRECAUTIONS: Disconnect brewer from electric power. Allow brewer to cool. FREQUENCY: Daily TOOLS: Mild Detergent, Clean Soft Cloth or Sponge Bristle Brush. Brewing and serving temperatures of coffee are extremely hot. Hot coffee will cause serious skin burns. CAUTION: 1. Disconnect brewer from electric power. SHOCK HAZARD Allow brewer to cool before cleaning. Do not submerge or immerse brewer in water. 2.
TROUBLESHOOTING SUGGESTIONS Water won’t heat Coffee level too high or low Brew chamber overflows Sprays water from brew head No brew while faucet flows OK No brew plus no flow from hot water faucet No flow from hot water faucet Poor coffee quality POSSIBLE CAUSE SUGGESTED REMEDY Brewer unplugged or circuit breaker tripped Check power supply cord, Check / reset circuit breaker Temperature adjusted too low or set to off Turn on and set for desired temperature.
ERROR DETECTION This brewer is designed to perform a continuous internal diagnosis, and to signal faults by flashing all the lights. In fault mode, warmers, heating element and water fill solenoid are turned “off”, and most keypad functions are disabled. Error detection (all lights flashing) will occur under two conditions: • Anytime a temperature in excess of 214ºF is detected. • Temperature does not change by at least 2ºF within 4 minutes of tank heater being energized (HEAT light on).
SERVICING INSTRUCTIONS WARNING: SHOCK HAZARD Opening access panels or removing warmer plates on this brew may expose uninsulated electrical components. Disconnect brewer from electrical power before removing any panel. ACCESS PANELS TOP PANEL: Remove top panel to access hot water tank, thermo probe, heating elements, brew circuit tubing, faucet valve and piping. Top panel is held by two screws at the rear and a retaining lip at the front.
SERVICING INSTRUCTIONS (continued) TEMPERATURE ADJUSTMENT WARNING: Unplug power cord or turn circuit breaker OFF. Remove top panel. Remove button plug from front panel. SHOCK HAZARD These procedures involve exposed electrical circuits. These procedures are to be performed by qualified technical personnel only. Fig. 13 Checking and Adjusting Brew Temperature Pull vent tube out of tank lid and insert a thermometer of known accuracy in vent hole. Reconnect brewer to electrical power.
SERVICING INSTRUCTIONS (continued) IMPORTANT: Water pressure must be between 20 p.s.i and 90 p.s.i. flowing pressure. If water pressure exceeds this value, or if water pressure varies greatly, a pressure regulator must be installed in the water supply line. IMPORTANT: Before setting assembly into tank, make sure tank lid gasket is properly seated on flange of lid. DO NOT OVER-TIGHTEN.
SERVICING INSTRUCTIONS (continued) REPLACE SOLENOID Unplug power cord. Turn OFF and disconnect water supply from brewer inlet fitting. Remove front panel. Remove two screws holding access door in place. Remove access door and solenoid. Unscrew inlet fitting cap to release solenoid from door. Remove wiring from solenoid. Large end of wrench 86660 can be used to hold solenoid inlet fitting while disconnecting supply line. REPLACE FAUCET SUPPLY HOSE Unplug power cord.
SERVICING INSTRUCTIONS (continued) IMPORTANT: When replacing water faucet coil, also replace seal gaskets. REPLACE HOT WATER FAUCET COIL (Symptom: Brewer drips continuously from brew head, except when faucet valve is turned OFF.) Remove tank lid assembly per above. Remove two hex nuts hot water coil to cover. Pull coil from mounting holes. Reassemble in reverse order.
SERVICING INSTRUCTIONS (continued) SET CONTROLLER JUMPERS Placing the jumper across Q1 sets Quality Time at 20 Minutes. Placing the jumper across Q2 sets Quality Time at 30 Minutes. Removing jumpers from both Q1 or Q2 disables Quality Timer. Placing the jumper across V1 sets Valve Time Range to 60 - 180 seconds. Removing jumper from V1 sets Valve Time Range to 10 - 80 seconds. REPLACE KEYPAD Unplug power cord or turn circuit breaker OFF. Shut off water supply valve. Remove top and front panels. Fig.
SERVICING INSTRUCTIONS (continued) CHEMICAL BURN HAZARD Deliming chemicals are caustic. Wear appropriate protective gloves and goggles during this procedure. Never siphon deliming chemicals or solutions by mouth. This operation should only be performed by qualified and experienced service personnel. IMPORTANT: DO NOT spill, splash or pour water or deliming solution into or over any internal component other than the inside of the water tank.
642 p/n 2M-75872 1080 1082 1086 1088 Owmers Manual NOTES: 21
EXPLODED VIEW & PARTS LIST HOT WATER TANK ASSEMBLY PART NO.
EXPLODED VIEW & PARTS LIST (continued) ELECTRICAL COMPONENTS ITEM DESCRIPTION USED ON 2E-72936 Switch, Rocker 125/250V 1086, 1088 31 2C-74859 Keypad All 36 2E-70353 Cord & Cap Assembly 1080, 1082 36t 2E-70709 Terminal Strip 1086, 1088 37 2K-70215 Strain Relief 1080, 1082 2V-70124 Valve-Sol, 120V Metal All .75GPM 2E-75753 Solenoid Bypass, 120V Plst. .50GPM All .
EXPLODED VIEW & PARTS LIST (continued) INTERNAL PLUMBING COMPONENTS PART NO.
EXPLODED VIEW & PARTS LIST (continued) CABINET COMPONENTS ITEM DESCRIPTION USED ON 21 2A-43201 Spacer .171 ID x .
WIRING DIAGRAM E.B.C.ô BREWER KEY PAD 1 P1 CONTROL BOARD 1 MODEL VOLTS WATTS AMPS 1080 1080CA 120 120 1800 1500 15 12 1082 1082CA 120 120 1800 1500 15 12 P2 TEMPERATURE PROBE POWER BOARD NEUTRAL IN VALVE B 2 HEATER B WHITE HI LIMIT BLACK VALVE A 5 3 INLET VALVE .
WIRING DIAGRAM (continued) E.B.C.™ BREWER KEY PAD 1 P1 VOLTS WATTS AMPS 1086 115/230 3500 15 1088 115/230 3500 15 CONTROL BOARD 1 P2 TEMPERATURE PROBE POWER BOARD NEUTRAL IN 2 VALVE B 5 BLACK 12 ga WHITE 12 ga WHITE HEATER B HI LIMIT 8 VALVE A 6 LINE IN 10 HEATER A HEATING ELEMENT 642 p/n 2M-75872 1080 1082 1086 1088 Owmers Manual MODEL INLET VALVE .
642 p/n 2M-75872 1080 1082 1086 1088 Owmers Manual NOTES 28
642 p/n 2M-75872 1080 1082 1086 1088 Owmers Manual NOTES 29
10 Sunnen Drive, St. Louis, MO 63143 telephone: 314-678-6336 fax: 314-781-2714 www.wellsbloomfield.