A. Adjust Brew Time
B. Adjust Brew Temperature
C. Adjust Quality Timer
D. Adjust Dripout Timer
E. Adjust After Hours Timer
AB
C DE
UNDER
TOP COVER
(IN SECONDS)
BREW
TIMER
(IN °F)
BREW
TEMP
(IN 5 MIN INCR)
QUALITY
TIMER
(IN SECONDS)
DRIPOUT
TIMER
(IN ONE HR INCR)
AFTER HOURS
TIMER
WATER
LEVEL
PROBE
TEMP
PROBE
20
185
6OFF
360
9030
70
120OFF
194
205OFF
210
320100
SERVICING — OPERATIONAL ADJUSTMENTS
CAUTION:
Electric Shock Hazard
Unplug or disconnect the brewer from electric
power before removing the top cover
IMPORTANT: Adjustments must be performed
by a qualified technician ONLY.
1. Access the Controls: All adjustments on
the E-Max™ LX may be accessed by
removing the top cover or top warmer station
from the brewer. The adjustments are
directly behind the front panel.
2. Adjust Brew Time: The time the brew
solenoid is open maybe adjusted by turning
the shaft of the left-most control (A). Turning
the shaft clockwise increases the time. Ten
degrees of rotation is approximately equal to
seven seconds change. Adjust until a
complete brew is achieved without
overflowing the airpot or server.
3. Adjust Brew Temperature: Ideal brewing
temperature is 195ºF to 205ºF. Realistically,
the maximum brew temperature is the local
boiling temperature minus 10ºF. To adjust
the temperature, turn the shaft of the second
control (B). Turning the shaft clockwise
increases temperature. Fifteen degrees of
rotation is approximately equal to 1-1/4ºF.
4. Quality Timer: (not used on airpot and
thermal brewers).
5. Adjust Dripout Timer: This feature
disables the brew switch for an amount of
time to allow all water to finish dripping
through the grounds. The length of time may
be adjusted by turning the shaft of the fourth
control (D). Turning the shaft clockwise
increases the time. Ten degrees of rotation
is approximately equal to 2-1/2 seconds.
6. Adjust After Hours Timer: This feature
places the brewer into an energy-saver
mode if no brew has been initiated for a
length of time. Time may be adjusted by
turning the shaft of the fifth control (E).
Turning the shaft clockwise increases the
time. Turning the shaft fully counter-
clockwise turns the After Hours function off.
Adjustment is in one hours incremen
ts.