Specifications
TROUBLESHOOTING SUGGESTIONS
10
606 Owners Manual for 8742-8748 Tea Brewer 2M-76116
606 Owners Manual for 8742-8748 Tea Brewer 2M-76116
SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY
Water won’t heat
Brewer unplugged or circuit breaker
tripped
Check power supply cord
Check / reset circuit breaker
Temperature setpoint too low Set for desired temperature
Hi-Limit safety switch tripped Allow to cool hi-limit will self-reset
Damaged internal component or wiring
Examine wiring & connectors, controller, power
board and heating element, Repair/replace as
needed
Tea level too high or low Timer out of adjustment Adjust timer
Brew chamber overows
Too many lter papers or wrong lter
paper
Use one (1) genuine Bloomeld lter per brew
Brew chamber dispense hole plugged Thoroughly clean brew chamber
Too much tea leaves Use correct amount of tea
Sprays water from brew
head
Spray gasket improperly installed Check/reinstall gasket on INSIDE of brew head
No brew
Spray disk plugged Clean spray disk
Damaged internal component or wiring
Check switches, timer and solenoid. Repair,
replace as needed
Water supply OFF Turn water supply ON
“Y” Strainer or solenoid inlet strainer
plugged
Clean strainer
Water lter (if used) plugged Replace lter element
Poor tea quality
Keep brewer and dispenser clean.Install a taste and odor lter in water supply, and replace
cartridges regularly. Use a quality fresh supply of tea leaves. Use the amount of tea leaves
appropriate to brew volume. The needle valve adjusts the ratio of brew water to dilution
water. Set the needle valve to adjust the strength of the nal brew.