SERVICING INSTRUCTIONS (continued)
12
TEMPERATURE ADJUSTMENT
Unplug power cord or turn circuit breaker OFF. Remove top
panel.
Pull vent tube out of tank lid and insert a thermometer of known
accuracy in hole. Reconnect brewer to electrical power.
Place empty container under brew chamber. Energize brewer
and allow unit to heat. When the READY TO BREW light rst
glows, read the temperature displayed on thermometer.
Adjust thermostat by turning shaft; clockwise increases
temperature. 1/8 turn = approximately 10ºF, or 5.6ºC.
Refer to Table 1 below for proper brewing temperature based on
altitude.
Upon completion, remove thermometer and reinstall the vent line
and top panel.
Fig. 9 Checking and Adjusting Brew Temperature
CAUTION:
SHOCK HAZARD
These procedures involve
exposed electrical circuits.
These procedures are to
be performed by qualied
technical personnel only.
NOTE: Optimum brewing
temperature is 195ºF to 205ºF
(90ºC to 96ºC).
Thermostat should be adjusted
to a maximum temperature of
200ºF (95ºC).
IMPORTANT:
A mechanical thermostat will
maintain temperature within
±5ºF.
To prevent boiling water in
the brewer, controller should
be adjusted to a maximum
temperature equal to the local
boiling temperature minus 5ºF,
or 200ºF (94ºC), whichever is
less.
NOTE: 1/8 turn = approximately
10ºF (5.6ºC).
Table 1 Boiling Temperature by Altitude
Fig. 10 Adjust Thermostat
606 Owners Manual for 8742-8748 Tea Brewer 2M-76116