BLOOMFIELD INDUSTRIES 2 ERIK CIRCLE, P. O. Box 280 Verdi, NV 89439 Customer Service (775) 345-0444 Ext.502 fax: (775) 345-0569 www.wellsbloomfield.
WARRANTY STATEMENT The prices charged by Bloomfield Industries for its products are based upon the limitations in this warranty. Seller’s obligation under this warranty is limited to repair of defects without charge by a Bloomfield Industries Authorized Service Agency or one of its sub-agencies. This service will be provided on customer’s premises for non-portable models.
TABLE OF CONTENTS WARRANTY STATEMENT GENERAL USE AND CARE PRECAUTIONS & GENERAL INFORMATION OPERATION CLEANING MAINTENANCE (Deliming) TROUBLESHOOTING SUGGESTIONS xi 2 3 4 5 6 8 Proper installation, professional operation and consistent maintenance of this appliance will ensure that it gives you the very best performance and a long, economical service life. IMPORTANT: This is a general guide only. Always refer to the specific manual for your equipment.
GENERAL USE AND CARE KEEP IT DRY 3. Use the proper tools in the proper way to clean your Bloomfield equipment: a. Soft cloth and plastic scouring pads are generally safe to use on stainless steel. b. Stainless steel pads may be used ONLY IF the scrubbing motion is in the direction of the visible grain. DO NOT use a circular motion. c. In the absence of visible grain, use only soft cloth or plastic pads. Scrub only in a linear motion along the longest axis of the equipment. d.
PRECAUTIONS AND GENERAL INFORMATION Bloomfield brewers are intended for use in commercial establishments only. Unless otherwise stated, Bloomfield brewers are intended to hot beverages for human consumption. No other use is recommended or authorized by the manufacturer or its agents. Operators of the equipment must be familiar with the appliance use, limitations and associated restrictions. Operating instructions must be read and understood by all persons using or installing this appliance.
OPERATION CAUTION: Hot Surface Exposed surfaces can be hot to the touch and may cause burns. BREWING TEA 1. Use a clean brew chamber. Inspect the brew chamber to ensure that it is free from tea leave from the previous brew. CAUTION: Hot Brew chamber and contents will be hot. 2. Be sure the wire rack is in place in the bottom of the brew chamber. 3. Insert one (1) genuine Bloomfield paper filter in the bottom of the brew chamber. 4. Pour the proper amount of fresh tea leaves into the brew chamber. 5.
CLEANING PROCEDURE: Clean Tea Brewer PRECAUTIONS: Disconnect brewer from electric power. Allow brewer to cool. FREQUENCY: Daily TOOLS: Mild Detergent, Clean Soft Cloth or Sponge Bristle Brush. 1. Disconnect brewer from electric power. Allow brewer to cool before cleaning. CAUTION: Burn Hazard Brewing and serving temperatures of coffee are extremely hot. Hot coffee will cause serious skin burns. CAUTION: Electric Shock Hazard Do not submerge or immerse brewer in water. 2. Remove and empty dispenser.
MAINTENANCE CAUTION CHEMICAL BURN HAZARD Deliming chemicals are caustic. Wear appropriate protective gloves and goggles during this procedure. Never siphon deliming chemicals or solutions by mouth. This operation should only be performed by qualified and experienced service personnel. IMPORTANT: DO NOT spill, splash or pour water or deliming solution into or over any internal component other than the inside of the water tank.
MAINTENANCE (continued) 7. Set the tank back into the brewer. Reassemble the tank lid to the water tank. Make sure the gasket is properly in place, then reinstall the hold-down strap. 8. Reinstall wiring to heating element and thermostat. Reinstall the hi-limit thermostat (if removed). For brewers with hot water faucet, reassemble faucet piping. Verify that all internal components are dry, then reinstall the top panel. 10.
TROUBLESHOOTING SUGGESTIONS SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY Water won’t heat Brewer unplugged or circuit breaker tripped Check power supply cord Check / reset circuit breaker Thermostat set too low Set for desired temperature Hi-Limit thermostat tripped Allow to cool Reset hi-limit (8786, 8788) Damaged internal component or Examine wiring & connectors, wiring thermostat and heating element Repair/replace as needed Coffee level too high or low Timer out of adjustment Adjust timer Brew ch
NOTES AUTHORIZED BLOOMFIELD SERVICE CENTER CONTACT ADDRESS PHONE # 9
Bloomfield Industries, Inc. Division of Carrier Refrigeration PO. Box 280 Verdi, NV. 89439 Telephone (775)345-0444 Fax (888)492-2783 Service: (888)492-2782 website: www.wellsbloomfield.com Bloomfield Industries Canada Limited Division of Carrier Refrigeration 5850 Keaton Cresent Mississauga, Ontario, Canada L5R 3K2 Telephone (905)507-1700 Fax (905)507-1777 Toll Free (877)507-1700 website: www.bloomcan.com e-mail: brewinfo@bloomcan.