671 10 Sunnen Drive St. Louis, MO 63143 telephone: 314-678-6336 fax: 314-781-2714 www.bloomfieldworldwide.com OWNERS MANUAL for SINGLE & DUAL SATELLITE COFFEE BREWER with ELECTRO-MECHANICAL CONTROL and EXTERNALLY HEATED SATELLITE SERVERS MODEL: 9121 9221 Includes: Installation Operation Use & Care Servicing Instructions Model 9121 Single Satellite Brewer p/n 2M-Z16955 Rev.
WARRANTY STATEMENT All equipment manufactured by Bloomfield is warranted against defects in materials and workmanship for the time periods listed in the chart starting from the date the equipment is placed into service and is for the benefit of the original purchaser: Equipment pod brewers ECO brewers airpots dispensers; i.e.
TABLE OF CONTENTS WARRANTY STATEMENT SPECIFICATIONS FEATURES & OPERATING CONTROLS PRECAUTIONS & GENERAL INFORMATION AGENCY APPROVAL INFORMATION INSTALLATION OPERATION CLEANING INSTRUCTIONS SERVICING INSTRUCTIONS Delime the water tank Draining hot water tank Timer Adjustment Temperature Adjustment TROUBLESHOOTING SUGGESTIONS EXPLODED VIEWS WIRING DIAGRAM xi 1 2 4 4 5 7 10 12 12 13 14 15 16 17 26 Thank You for purchasing this Bloomfield appliance.
FEATURES AND OPERATING CONTROLS BREW CHAMBER (IN POSITION) FUSE (BEHIND FRONT PANEL) SALELLITE (IN POSITION) HOT WATER FAUCET WARMER SWITCHES Fig 1.
FEATURES AND OPERATING CONTROLS (continued) Brewer Adjustable Legs Allows brewer to be leveled. Also allow clearance for cleaning underneath brewer. Brewing Controls Start or stop brew and select brew volume. Right and left section are independent. Bypass Nozzle Dilution water flows into brew chamber channel from here. Dilution water DOES NOT flow through the coffee grounds. Heater Switch Turns power to tank heater ON or OFF. Hot Water Faucet Hot water dispensed here.
GENERAL INFORMATION AND PRECAUTIONS WARNING: SHOCK HAZARD All servicing requiring access to non-insulated electrical components must be performed by a factory authorized technician. DO NOT open any access panel that requires the use of tools. Failure to follow this warning can result in severe electrical shock. CAUTION: BURN HAZARD Surfaces of this brewer can be hot and can cause burns on contact. This appliance is intended for use in commercial establishments only.
INSTALLATION INSTRUCTIONS INSTALL LEGS The brewer is provided with 4” adjustable legs and rubber feet. Be sure the legs are securely screwed into the base of the brewer, and that the rubber feet are properly installed. LEVEL THE UNIT The adjustable legs allow the brewer to be leveled. Set the brewer in its ultimate operating location and check for level with a spirit level Adjust the brewer for level from front-to-rear, and from side-to-side. Be sure all four feet rest firmly on the counter.
INSTALLATION INSTRUCTIONS (continued) IMPORTANT: Initial set-up must be performed by a qualified installer or qualified service technician. Improper set-up will damage the brewer and void the warranty. IMPORTANT: Complete water line installation before connecting brewer to electrical power. MAKE SURE THE FRONT PANEL “HEATER ON/ OFF” SWITCH IS IN THE OFF POSITION BEFORE CONNECTING BREWER TO ELECTRICAL POWER. DO NOT turn the HEATER ON/ OFF switch on until the water tank is filled.
OPERATING INSTRUCTIONS 1 1/2 GAL 1 GAL START BREW STOP BREW VOLUME SELECT 1 1/2 GAL READY TO BREW 1 GAL HEATER ON / OFF VOLUME SELECT Fig. 3 Control Panel START BREW IL2305, M671 GETTING STARTED Check the brewer and satellites: Check that the brewer is clean and the drip tray (if used) is empty. Check that the satellites are empty and clean with lids properly installed. Check the spray heads: Remove the brew chambers. Check the spray heads.
OPERATING INSTRUCTIONS (continued) 1 1/2 GAL 1 GAL START BREW STOP BREW Fig. 4 Operating Controls PAPER FILTER VOLUME SELECT 1 1/2 GAL READY TO BREW HEATER ON / OFF 1 GAL VOLUME SELECT STOP BREW START BREW BREWING COFFEE IL2305, M671 Prepare the Brew Baskets: Make sure the bypass diverter is properly installed in each brew chamber. Insert one (1) Bloomfield paper filter into each brew chamber. BREW CHAMBER Add a measured amount of grounds to each brew basket.
OPERATING INSTRUCTIONS (continued) WATER FLOW IL2307 INLET The INLET VALVE is controlled by a signal from the CONTROL BOARD. If the WATER LEVEL PROBE does not detect water, the inlet solenoid is opened until water is again sensed. The 9221-Series of brewers have two independent brewing systems sharing a common hot water tank. 671 2M-Z16955 Owners Manual 9221 Dual Satellite Brewer BREW AND BYPASS The BREW VALVE fed by gravity from the hot water tank.
CLEANING INSTRUCTIONS CLEANING INSTRUCTIONS CAUTION: BURN HAZARD Brewing and serving temperatures of coffee are extremely hot. Hot coffee will cause serious skin burns. IMPORTANT: DO NOT use steel wool, sharp objects, or caustic, abrasive or chlorinated cleansers to clean the brewer, brew baskets or satellites. DO NOT immerse or submerge satellites in water. PROCEDURE: Clean Coffee Brewer PRECAUTIONS: Press POWER key to OFF. Allow brewer to cool.
CLEANING INSTRUCTIONS (continued) PROCEDURE: Clean Satellite CAUTION: PRECAUTIONS: Drain Satellite before Cleaning FREQUENCY: Twice Weekly TOOLS: Sight Glass Brush, Sanitizer Soft Clean Cloth, Bucket BURN HAZARD Brewing and serving temperatures of coffee are extremely hot. Hot coffee will cause serious skin burns. IMPORTANT: DO NOT submerge satellite in water. 1. Remove and drain satellites. Remove lids. 2. Place 1 packet of Sanitizer into 2-1/2 gallons of warm tap water.
SERVICING INSTRUCTIONS CAUTION: CHEMICAL BURN HAZARD Deliming chemicals may be caustic. Wear appropriate protective gloves and goggles during this procedure. Never siphon deliming chemicals or solutions by mouth. PROCEDURE: Delime the Water Tank PRECAUTIONS: Disconnect brewer from electric power. Allow brewer to cool.
SERVICING INSTRUCTIONS (continued) 10. Reinstall tank lid assembly into hot water tank. Make sure the lid gasket is properly in place, then reinstall the holddown clamps. 11. Remove spray disks and gaskets. Rinse both brew heads with clean water. Using a stiff brush, scrub spray disk to remove any lime or calcium build-up. Reinstall gaskets and spray disks. 13. Reconnect brewer to electrical supply . 14. Install the brew chamber without filter paper or grounds. 15.
SERVICING INSTRUCTIONS (continued) TIMER ADJUSTMENT CAUTION: SHOCK HAZARD Disconnect brewer from electric power before opening the access panel. Adjustments to be performed by qualified technician only. NOTE: Brewer is pre-adjusted to deliver 1 and 1-1/2 gallons of coffee at a water pressure of 50 p.s.i. Use this procedure to adjust the delivered volume to suit local conditions. PRECAUTIONS: Disconnect brewer from electric power. Allow brewer to cool.
SERVICING INSTRUCTIONS (continued) TEMPERATURE ADJUSTMENT CAUTION: PRECAUTIONS: Disconnect brewer from electric power. Allow brewer to cool. SHOCK HAZARD FREQUENCY: As required to adjust delivered volume TOOLS: Phillips head screwdriver Satellite or other container to calibrate volume 1. Press HEATER ON/OFF switch to OFF. Turn POWER switch on back of brewer OFF. 2. Remove TOP PANEL. Operating controls are accessible through the top panel only. 3.
TROUBLESHOOTING SUGGESTIONS DESCRIPTION OF PROBLEM No lights or heat No heat Brewer overflows Brew chamber overflows Heats slow No heat to satellite Poor coffee quality SUGGESTED REMEDY Unit not plugged in or circuit breaker tripped Restore electric power Power switch OFF Turn power switch ON Hi-limit safety tripped Allow brewer to cool, verify water level, reset hi-limit Thermostat damaged Replace thermostat Damaged hi-limit safety Replace hi-limit Damaged heater switch Replace heater s
SATELLITE EXPLODED VIEW & PARTS LIST SATELLITE MODEL 9440 4.1 4.2 2 4.8 4.9 4.6 4.4 4.5 4.7 PART OF ITEM 4 7 6 5 9 1 11 8 2 PL 10 4 3 P/N: BLSRLH 74337 Rev. D 02/12/04 IL1855b SATELLITE ASSEMBLY 9440 671 2M-Z16955 Owners Manual 9221 Dual Satellite Brewer Fig No 1 2 3 4 4.1 4.2 4.4 4.5 4.6 4.7 4.8 4.
EXPLODED VIEW 9221 CABINET AND EXTERIOR COMPONENTS 671 2M-Z16955 Owners Manual 9221 Dual Satellite Brewer 18 IL2309, PL671
PARTS LIST : 9221 CABINET AND EXTERIOR COMPONENTS Model: Dual Satelite Brewers, Cabinet & Exterior Comp Fig No.
EXPLODED VIEW 9221 INTERIOR COMPONENTS 20 671 2M-Z16955 Owners Manual 9221 Dual Satellite Brewer IL2310, PL671
PARTS LIST: 9221 INTERIOR COMPONENTS Model: Dual Satelite Brewers, Interior Components Fig No. Qty Description 1 D7-73778 4 RETAINING CLIP TANK LID 3 2I-70147 1 GASKET TANK COVER 4 2U-71061 1 FAUCET HOT WATER 5 D7-76576 2 BRKT OUTLET VALVE 6 A6-73521 1 PROBE ASSY WATER LEVEL 7 2A-73532 1 SLEEVE WATER LEVEL PROBE 8 2I-72390 1 GROMMET .375 ID TRANSLUCE 9 F4-73978 1 TUBE SIL .
EXPLODED VIEW 9121 CABINET AND EXTERIOR COMPONENTS 1 2 3 9 4 10 5 6 11 7 8 12 13 14 15 16 17 18 19 20 32 21 33 22 23 34 24 35 1 31 1 See Detail A 28 29 36 27 37 26 38 25 39 40 Model: 9121, Single Satellite Brewer SK2651 22 Rev.
PARTS LIST : 9121 CABINET AND EXTERIOR COMPONENTS Model 9121: Single Satelite Brewers, Main Assy Fig No.
EXPLODED VIEW CABINET AND EXTERIOR COMPONENTS 3 2 4 5 6 7 1 8 9 10 11 12 14 17 16 15 Detail A Model: 9121, Single Satellite Brewer Tank Assy SK2652 24 Rev.
PARTS LIST : CABINET AND EXTERIOR COMPONENTS Model 9121: Single Satelite Brewers, Tank Assy Fig No. Qty Description 1 2I-72390 1 GROMMET .375 ID TRANSLUCE 2 2A-74343 1 TUBE FILL 90 DEGREE 3 D7-73414 1 SHIELD HI-LIMIT 4 2T-73312 1 THERMO HI LIMIT DBL POLE 5 2C-73415 2 NUT 6-32 HEX 1.00 LG ALUM 6 671 2M-Z16955 Owners Manual 9121, 9221 Dual Satellite Brewer Part Number A6-73521 L2-75976 1 PROBE ASSY WATER LEVEL 120/240V, 230V PROBE ASSY WATER LEVEL 1.
WIRING DIAGRAM: 9221 DUAL SATELLITE BREWER HZ 50/60 15 17 13 16 17 BLACK WHITE WHITE 6 ORANGE BLACK POWER SWITCH BLUE LOAD L2 AMPS 23/26.
WIRING DIAGRAM: 9121 SINGLE SATELLITE BREWER AMPS 3150 13.
WIRING DIAGRAM: 9121-230V SINGLE SATELLITE BREWER POWER SWITCH DPST HI LIMIT SWITCH 230V HEATER SWITCH HTG ELEMENT RIGHT 120V 1500W WARMER SWITCH INLET VALVE STOP BREW SWITCH MOM NC TIMER L1 THERMOSTAT WIRE L2 LOAD T3 L3 BREW LIGHT LIQUID LEVEL PROBE RED T2 L2 YELLOW 1 1/2G JUMPER MAX 1G VOLUME SELECT SWITCH NC INPUT WARMER ELEMENT COM DUMP VALVE TANK GROUND HTG ELEMENT LEFT 120V 1500W LIQUID LEVEL BOARD N T1 L1 CONTACTOR NO POWER SWITCH DPST HI LIMIT SWITCH MODEL VOLTS
671 2M-Z16955 Owners Manual 9121, 9221 Dual Satellite Brewer NOTES 29
10 Sunnen Drive, St. Louis, MO 63143 telephone: 314-678-6336 fax: 314-781-2714 www.bloomfieldworldwide.