Operating instructions

PROGRAMMING PROCEDURES
10
All 6 volumes are set
Independently.
Left and right side may
be set the same or
different. See program
chart.
Maximum Water temp is
factory set at 208ºF. It
may be adjusted from
195ºF to 210ºF.
Maximum Brew Temp.
can be set no higher than
5ºF below the Maximum
Water Temperature.
When using the timer be
sure to allow at least 30
minutes for the brewer to
reach proper temperature
from th e ti me i t i s tu rn ed
on.
Brew Settings Menu
"Water Temp:" is actual water temperature in the tank.
"Brew Temp:" is desired brew temperature. This temperature +/-IºF will
be maintained in the tank. Adjust by pressing 5th or 6th keys. The
brew temperature cannot be set any higher than 5ºF below the
Maximum Water Temperature, which is factory set at 208ºF. This
means maximum brew temperature will be 20F. If a higher
temperature is required, first increase the Maximum Water
Temperature in Machine settings (maximum is 210ºF), then increase
brew temperature (maximum brew temperature is 205'F if Maximum
Water Temperature is increased to 210ºF).
• Pulse Brew. To access the pulse or pre-infusion programs, see Pulse
Brew System details.
• "Total Valve:". This is the number of seconds the dump (or brew) valve
will remain open and determines total water volume.
Brew Type for each volume can be set as airpot or satellite container.
Note: "Airpot" brew type bypasses any satellite interlock system.
• "Brew Complete...:" (Dripout Time)- This is the number of seconds after
the dump valve is closed that is required until all of the water flows
through the brew basket. If different weights of coffee or tea are used,
this number may need to be increased or decreased.
Time Functions Menu
"After Hours:" When After Hours™ is activated, the brewer will allow the
water temperature to drop by 20'F before reheating. Can be turned off
by setting to "0".
"Quality Time:" - Countdown Quality Timer. Flashes SATELLITE
LED after a set time to remind server that coffee is aged. Can be
turned off by setting to "0", or set from 0 minutes to 180 minutes. See
program tabl e.
• "Timer:" Turn the timer on if automatic startup and stop is required.
Ti me for the brewer is maintained with a battery backup system that will
last up to 20 years. This system also handles power fluctuations by
maintaining the power time during power outages. When setting times,
make sure that the AM or PM is set properly to activate the timer at the
correct time. On and Off times for weekdays and weekends are set
individually. Weekend may be turned "OFF" by setting the start and
stop time at the same time.
• "Day:" Set the day of the week by using the 5th and 6th keys.
"Time:" Use the 5th and 6th keys to set Hour, AM or PM and Minutes.
Service & Counters Menu
• "TotalVol:" - Total Volume. Indicates total water volume processed by
the brewer.
• "Brew Cycs:" - Brew Cycles. Displays total number of brew cycles since
l a st re se t .
"Filter Message" - Select one of three messages to be displayed if filter
exceeds life expectancy, or "0" to turn filter message "OFF".
• "FltrLife:" - Filter Life. If a filter is used, input the number of gallons of
expected filter life capacity, in increments 100 gallons.
"Message" Trouble message to be displayed. Programmed with
personal computer.
675 p/ n 74346 SS-2 Programming Manual