672 BLOOMFIELD INDUSTRIES 10 Sunnen Drive St. Louis, MO 63143 telephone: 800-807-9054 fax: 314-781-2714 www.wellsbloomfield.com OWNERS MANUAL for SS2 - SERIES DUAL SATELLITE COFFEE BREWERS with ELECTRONIC PROGRAMMABLE CONTROL and INTERNALLY HEATED SATELLITE SERVERS MODELS: 9520 9521 9520FB 9521FB Includes: Installation Operation Use & Care Servicing Instructions Model 9520 Dual Satellite Brewer with optional 3901 Drip Tray DD-74345 Rev.
WARRANTY STATEMENT All electrical equipment manufactured by WELLS BLOOMFIELD is warranted against defects in materials and workmanship for a period of one year from the date of original installation or eighteen (18) months from the date of shipment from our factory, whichever comes first, and is for the benefit of the original purchaser, except that: a. airpots carry a 30 day parts warranty only. b. dispensers; i.e., tea and coffee carry a 90 days parts warranty only, decanters excluded.
TABLE OF CONTENTS WARRANTY STATEMENT SPECIFICATIONS FEATURES & OPERATING CONTROLS PRECAUTIONS & GENERAL INFORMATION AGENCY APPROVAL INFORMATION INSTALLATION OPERATING INSTRUCTIONS CLEANING INSTRUCTIONS PROGRAMMING INSTRUCTIONS TROUBLESHOOTING SUGGESTIONS SERVICING INSTRUCTIONS EXPLODED VIEWS / PARTS LISTS WIRING DIAGRAM 9340 EXPLODED VIEW / PARTS LIST / WIRE DIA Thank You for purchasing this Wells Bloomfield appliance.
DD-74345-M672 OP MANUAL DUAL SATELLITE BREWERS FEATURES AND OPERATING CONTROLS Fig 1.
FEATURES AND OPERATING CONTROLS (continued) Brewer Adjustable Legs Allows brewer to be leveled. Also allow clearance for cleaning underneath brewer. Brewing Controls Start or stop brew and select brew volume. Right and left section are independent. Also, used to program brewer in programming mode. Connector Connects to satellite. Allows satellite heater to be energized. Allows brewer to sense that a satellite is in place. Digital Readout Displays information pertaining to brew cycle and status.
GENERAL INFORMATION AND PRECAUTIONS WARNING: SHOCK HAZARD All servicing requiring access to non-insulated electrical components must be performed by a factory authorized technician. DO NOT open any access panel that requires the use of tools. Failure to follow this warning can result in severe electrical shock. CAUTION: BURN HAZARD Surfaces of the brewer and brew chamber may be hot to the touch and can cause burns on contact. This appliance is intended for use in commercial establishments only.
INSTALLATION INSTRUCTIONS INSTALL LEGS The brewer is provided with adjustable legs and rubber feet. Be sure the legs are securely screwed into the base of the brewer, and that the rubber feet are properly installed. LEVEL THE UNIT The adjustable legs allow the brewer to be leveled. Set the brewer in its ultimate operating location and check for level with a spirit level Adjust the brewer for level from front-to-rear, and from sideto-side. Be sure all four feet rest firmly on the counter.
INSTALLATION INSTRUCTIONS (continued) DO NOT CONNECT POWER TO BREWER WITH SATELLITES IN PLACE. NOTE: If “NO WATER SENSED” error message is displayed: * Disconnect brewer from electrical power. * Review Plumber’s Installation Instructions * Check inlet solenoid for debris and verify proper operation NOTE: Brewer will not operate unless a satellite is properly positioned on the brewer.
OPERATING INSTRUCTIONS Fig. 3 Control Panel GETTING STARTED Check the brewer and satellites: Check that the brewer is clean and the drip tray (if used) is empty. Check that the satellites are empty and clean with lids properly installed. Check the spray heads: Remove the brew chambers. Check the spray heads. Verify that the spray disks are clean and properly installed. Verify that the gaskets are properly installed inside the spray heads. Check the brew chambers: Check that the brew chamber is clean.
OPERATING INSTRUCTIONS (continued) PAPER FILTER WIRE RACK BREW CHAMBER Fig. 5 Brew Basket CAUTION: BURN HAZARD Basket and contents are hot to the touch and may cause burns on contact. BREWING COFFEE Prepare the Brew Baskets: Make sure the wire rack is properly installed in each brew chamber. Insert one (1) Bloomfield paper filter into each brew chamber. Make sure the filter is properly supported by the wire rack. Add a measured amount of grounds to each brew basket.
OPERATING INSTRUCTIONS (continued) WATER FLOW Fig. 6 Water Flow Diagram DD-74345-M672 OP MANUAL DUAL SATELLITE BREWERS INLET The INLET VALVE is controlled by a signal from the CONTROL BOARD. If the WATER LEVEL PROBE does not detect water, the inlet solenoid is opened until water is again sensed. The SS-2 Brewer has two independent brewer systems sharing a common hot water tank. BREW The BREW VALVE fed by gravity from the hot water tank, and is controlled by a signal from the CONTROL BOARD.
CLEANING INSTRUCTIONS BURN HAZARD Brewing and serving temperatures of coffee are extremely hot. Hot coffee will cause serious skin burns. WARNING: SHOCK HAZARD DO NOT immerse or submerge satellites. Fluid may saturate the insulation and short-circuit the receptacle connectors. Electric shock may cause injury and property damage. IMPORTANT: DO NOT use steel wool, sharp objects, or caustic, abrasive or chlorinated cleansers to clean the brewer, brew baskets or satellites.
CLEANING INSTRUCTIONS (continued) PROCEDURE: Clean Satellite CAUTION: PRECAUTIONS: Drain Satellite before Cleaning FREQUENCY: Twice Weekly TOOLS: Sight Glass Brush, Sanitizer Soft Clean Cloth, Bucket Brewing and serving temperatures of coffee are extremely hot. Hot coffee will cause serious skin burns. WARNING: 1. Remove and drain satellites. 2. Place 1 packet of Sanitizer into 2-1/2 gallons of warm tap water. Pour approximately 1 gallon of sanitizer solution into each satellite.
PROGRAMMING INSTRUCTIONS Fig. 7 Function Keys NEW MENU SETTINGS For advanced programming features and instructions, refer to PROGRAMMING MANUAL, p/n 74346. This brewer can be programmed with a personal computer. Please contact your Bloomfield Representative for details Menu Program: Press POWER key to enter OFF mode.
PROGRAMMING INSTRUCTIONS (continued) FEATURES 1. Energizing the Brewer: Turn the brewer on by pressing the POWER key. The brewer will start to fill the tank with the message on the screen “filling…”. With the proper water supply the tank should be filled in about 2½ minutes. Once filled, the heating element will come on until the proper tank temperature has been reached, (which will take about 20 minutes on 120-Volt models or about 12 minutes on 120/240 Volt models).
PROGRAMMING (continued) ON/OFF – Normal Operation (Non Automatic Timer): To turn the brewer OFF, press the POWER key: 2 beeps will be heard and the brewer will be turned OFF, indicated by all lights being off. 5. View Water Temperature in Tank: To view the water temperature on the screen, the brewer must be ON, and not brewing or in the filling mode. Press and hold the 4th key, and depress the 6th key. The actual water temperature will be displayed for 3 seconds.
PROGRAMMING (continued) 7. Automatic Start-Up in Previous Mode: If the Satellite Brewer automatic timer is OFF (the factory setting) and power is disconnected, the brewer will start up when power is restored, in the mode it had been in prior to the power disconnection. If the Satellite Brewer has the timer setting ON and power is disconnected, the brewer will start up in the mode that it should be in at the time the power is restored. 8.
PROGRAMMING (continued) The factory programming has the After Hours™ mode turned OFF. While in the After Hours mode, the POWER LED will flash continuously. 12. After Hours™: The After Hours™ can be programmed to come on from 1 to 6 hours after the last brew. When the Brewer goes into the After Hours™ mode, the water in the tank will be allowed to drop from the normal brewing temperature and will reheat less frequently – this feature saves energy and extend component life.
TROUBLESHOOTING SUGGESTIONS DESCRIPTION OF PROBLEM No lights or heat No heat Brewer overflows Brew chamber overflows Heats slow Slow to fill DD-74345-M672 OP MANUAL DUAL SATELLITE BREWERS Satellite does not heat Satellite shorts out POSSIBLE CAUSE SUGGESTED REMEDY Unit not plugged in or circuit breaker tripped Restore electric power Power switch OFF Turn power switch ON Hi-limit safety tripped Allow brewer to cool, verify water level, reset hi-limit Water level probe corroded Clean water l
SERVICING INSTRUCTIONS CAUTION: CHEMICAL BURN HAZARD Deliming chemicals are caustic. Wear appropriate protective gloves and goggles during this procedure. Never siphon deliming chemicals or solutions by mouth. This operation should only be performed by qualified and experienced service personnel. IMPORTANT: DO NOT spill, splash or pour water or deliming solution into or over any internal component other than the inside of the water tank.
SERVICING INSTRUCTIONS (continued) 10. Reinstall tank lid assembly into hot water tank. Make sure the lid gasket is properly in place, then reinstall the holddown clamps. 11. Remove spray disks and gaskets. Rinse both brew heads with clean water. Using a stiff brush, scrub spray disk to remove any lime or calcium build-up. Reinstall gaskets and spray disks. 13. Reconnect brewer to electrical supply . 14. Install the brew chamber without filter paper or grounds. 15.
CABINET AND EXTERIOR COMPONENTS DD-74345-M672 OP MANUAL DUAL SATELLITE BREWERS EXPLODED VIEW 20
PARTS LIST - CABINET AND EXTERIOR COMPONENTS ITEM DESCRIPTION QTY ITEM 36 1 2 3 COVER TOP HOUSING SS2 TOP HOUSING WLD ASSY SS2 BODY WLD ASSY SS2 1 1 1 4 BASE WLD ASSY SDS-2 1 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 DD-74345-M672 OP MANUAL DUAL SATELLITE BREWERS PART NO 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 BTM PLATE WLD ASSY 1 PANEL BACK SS2 1 PANEL FRONT SS2 1 BRACKET CONTROL BOARD MTG 1 SS2 BRACKET TANK SUPPORT TOP SS2 2 2K-70229 BUSHIN
DD-74345-M672 OP MANUAL DUAL SATELLITE BREWERS EXPLODED VIEW INTERIOR COMPONENTS 22
PARTS LIST - INTERIOR COMPONENTS QTY ITEM SOLENOID SINGLE 120V 1.0 RETAINING CLIP TANK LID NUT 8-32 HEX HEAD KEPS MS GASKET TANK COVER FTG UNION 1/4X1/4 NUT 7/16-20 HEX HD BRASS TUBE INLET ASSY 9.62 WASHER SS .035X7/16IDX3/4OD FAUCET HOT WATER PROBE 8783MCD GROMMET 1/4 ID TRANSLUENT GROMMET .375 ID TRANSLU2I-72390 CENT A6-72661 TUBE SIL .
DD-74345-M672 OP MANUAL DUAL SATELLITE BREWERS EXPLODED WIRING DIAGRAM VIEW 24
SATELLITE EXPLODED VIEW, PARTS LIST & WIRING DIAGRAM SATELLITE ASSEMBLY 9340 120V L1 N E U T. 4 5W DD-74345-M672 OP MANUAL DUAL SATELLITE BREWERS S C H E M ATIC P /N 73 06 1 ITEM 1 PART NO 2L-73863 DESCRIPTION TANK LID ASSY, SRL-DP MODEL VOLTS WATTS 9340 120 45 QTY ITEM 1 13 WS-83172 PART NO RECEPTACLE PIN WIRED ASSY DESCRIPTION QTY 1 N.L.A.
10 SUNNEN DRIVE, P.O. BOX 430129, St. Louis, MO 63143 telephone: 314-781-2777 fax: 314-781-2714 www.wellsbloomfield.