687 OWNERS MANUAL For COFFEE BREWERS MODELS: 9600 SINGLE CUP INCLUDES: Installation Operation Use & Care Servicing Instructions Model: 9600 Single Cup Brewer PRINTED IN CHINA p/n 77195 Rev.
WARRANTY STATEMENT It also does not apply if the serial nameplate has been removed or unauthorized service personnel perform service. The prices charged by Bloomfield Industries for its products are based upon the limitations in this warranty. Seller’s obligation under this warranty is limited to the repair of defects without charge by a Bloomfield Industries Authorized Service Agency or one of its sub-agencies. This service will be provided on customer’s premises for non-portable models.
TABLE OF CONTENTS WARRANTY STATEMENT SPECIFICATIONS FEATURES & OPERATING CONTROLS PRECAUTIONS & GENERAL INFORMATION AGENCY LISTING INFORMATION INSTALLATION INSTRUCTIONS OPERATION Program Volume Select Keys Brew Coffee CLEANING INSTRUCTIONS TROUBLESHOOTING SUGGESTIONS SERVICING INSTRUCTIONS Deliming Instructions EXPLODED VIEW & PARTS LIST WIRING DIAGRAMS xi 1 2 3 3 4 7 8 9 10 11 12 17 18 21 Thank You for purchasing this Bloomfield Industries appliance.
FEATURES AND OPERATING CONTROLS - AUTOMATIC BREWERS Fig.
PRECAUTIONS AND GENERAL INFORMATION WARNING: ELECTRIC SHOCK HAZARD All servicing requiring access to non-insulated components must be performed by qualified service personnel. Do not open any access panels which require the use of tools. Failure to heed this warning can result in electrical shock. WARNING: INJURY HAZARD All installation procedures must be performed by qualified personnel with full knowledge of all applicable electrical and plumbing codes.
INSTALLATION READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION IMPORTANT: To enable the installer to make a quality installation and to minimize installation time, the following suggestions and tests should be done before the actual unit installation is started: CAUTION: ELECTRICAL DAMAGE DO NOT plug in or energize this appliance until all Installation Instructions are read and followed. Damage to the Brewer will occur if these instructions are not followed. Unpack the unit.
INSTALLATION (continued) PLUMBER’S INSTALLATION INSTRUCTIONS CAUTION: Brewer should be connected to a POTABLE WATER, COLD WATER line. Flush water line before connecting to Brewer. ELECTRICAL DAMAGE DO NOT use a saddle valve with a self-piercing tap for the water line connection. Such a tap can become restricted by waterline debris. For systems that must use a saddle tap, shut off the main water supply and drill a 3/16” (minimum) tap for the saddle connection, in order to insure an ample water supply.
INSTALLATION (continued) WARNING: ELECTRICIAN’S INSTALLATION INSTRUCTIONS SHOCK HAZARD REFER TO ELECTRICAL SPECIFICATIONS - Page 1 Check the nameplate to determine correct electrical service required for the Brewer to be installed. Brewer must be properly grounded to prevent possible shock hazard. DO NOT assume a plumbing line will provide such a ground. Electrical shock will cause death or serious injury. IMPORTANT: Supply power must match nameplate for voltage and phase.
OPERATION Fig. 4 Water Flow Diagram A. START-UP For initial start-up, or if the brewer has not been used for an extended period of time: ♦ Be sure the water supply is properly connected and the water supply valve is turned ON. ♦ Be sure that TANK HEATER SWITCH is OFF before connecting brewer to electric power. ♦ Be sure the WATER TANK IS FILLED. IMPORTANT: Fill the water tank before energizing this brewer. 1. Connect brewer to electric power. Brewer will begin filling. When solenoid closes, tank is full.
OPERATION (continued) B. PROGRAM BREW VOLUMES ♦ Each BREW SELECT KEY is individually programmable. ♦ Keys may be programmed for pulse brewing to optimize contact times and extraction rates,. ♦ Up to 10 pulses may be programmed. Each pulse delay is fixed at 4 seconds. ♦ Dilution for each BREW SELECT KEY is individually programmable (usually used for brewing tea). 1. Load a fresh pod in the pod holder and lock the pod in place. Place an empty cup on the cup grid. See page 9. 2.
OPERATION - BREWING COFFEE 1. Unlock the pod holder by pulling the LOCKING LEVER fully forward. 2. Pull the BREW TRAY fully forward, then lower tray. NOTE: Normally, the brewer will automatically discard the last pod. If the brewer has not been used for some time, the used pod may need to be removed by hand. Deposit the used pod in the pod bin. 3. Center a fresh pod on the grid of the LOWER POD HOLDER. CAUTION: BURN HAZARD Exposed surfaces of the brewer may be HOT to the touch, and can cause serious burns.
CLEANING INSTRUCTIONS CAUTION: PROCEDURE: Clean Coffee Brewer BURN HAZARD Brewing and serving temperatures of coffee and tea are extremely hot. Hot beverage will cause serious skin burns. PRECAUTIONS: Disconnect brewer from electric power. Allow brewer to cool. FREQUENCY: Daily TOOLS: Mild Detergent, Clean Soft Cloth or Sponge Bristle Brush, Bottle Brush CAUTION: SHOCK HAZARD DO NOT submerge or immerse brewer in water. DO NOT pour, spill or splash water onto, into or over any internal component.
SANITIZING INSTRUCTIONS CAUTION: PROCEDURE: Sanitize Coffee Brewer BURN HAZARD PRECAUTIONS: None FREQUENCY: Weekly TOOLS: Pod Sanitizer Packet Empty Container Brewing and serving temperatures of coffee and tea are extremely hot. Hot beverage will cause serious skin burns. 1. Unlock the pod holder by pulling the LOCKING LEVER fully forward. 2. Pull the BREW TRAY fully forward. 3. Center a fresh POD SANITIZER PACKET on the grid of the LOWER POD HOLDER. 4. Slide the BREW TRAY fully to the rear. 5.
TROUBLESHOOTING SUGGESTIONS SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY Water won’t heat Tank heater switch OFF Press switch to ON Brewer unplugged or circuit breaker tripped Check power supply cord Check / reset circuit breaker Temperature setpoint too low Set for desired temperature Hi-Limit safety switch tripped Allow to cool hi-limit will self-reset Damaged internal component or wiring Examine wiring & connectors, controller, water level probe and heating element Repair/replace as needed Coffe
SERVICING INSTRUCTIONS ACCESS PANELS CAUTION: SHOCK HAZARD TOP PANEL: Remove top panel to access hot water tank, thermostat, heating elements, brew pump and tubing, brew solenoid, hot water dispenser solenoid and piping, pod holders and brew tray, Top panel is held by screws around the edge. Remove pod drawer to access bottom of brew tray. SOLENOID DOOR: Remove solenoid door to access solenoid plumbing connections. Solenoid door is held by two screws and a retaining lip.
SERVICING INSTRUCTIONS (continued) CAUTION: TEMPERATURE ADJUSTMENT SHOCK HAZARD Disconnect brewer from electric power. These procedures involve exposed electrical circuits. These procedures are to be performed by qualified technical personnel only. NOTE: Optimum brewing temperature range is 195ºF to 205ºF (90ºC to 96ºC). Pull vent tube out of tank lid and insert a thermometer of known accuracy in hole. Reconnect brewer to electrical power. Place empty cup on the cup grid.
SERVICING INSTRUCTIONS (continued) REMOVE TANK LID ASSEMBLY IMPORTANT: Before setting assembly into tank, make sure tank lid gasket is properly seated on flange of lid. DO NOT OVER-TIGHTEN. Fig. 8 Tank Lid Configuration Disconnect brewer from electric power. Turn OFF water supply. Remove top panel. Pull vent tube, inlet elbow and water level probe out of tank lid. Remove hi-limit thermostat from bracket. Disassemble brew valve bracket and faucet valve bracket from tank lid.
SERVICING INSTRUCTIONS (continued) REPLACE SOLENOID Symptom: Brewer will not flow water; or, brewer drips continuously from pod holder or brew nozzle. NOTE: Wrench p/n 86660 is designed to allow easy removal of flare nuts from the water inlet fitting IMPORTANT: Shut-off water to brewer and disconnect brewer from electric power before removing hoses or wiring. Fig. 9 Wrench #86660 Remove water supply flare fitting: a. Slide the 5/8" end of the wrench over the flats on the inlet fitting of the valve. b.
SERVICING INSTRUCTIONS (continued) CLEAN UPPER POD HOLDER CAUTION: Remove drip tray assembly and pod drawer. Slide brew tray fully forward. SHOCK HAZARD NOTE: Upper pod holder can be cleaned in place. It is not normally necessary to remove the pod holder from the carriage for cleaning. Remove retaining screw from spray disk. Remove disk from pod holder. Remove upper ring plate and ring gasket from pod holder body. If necessary, remove retaining screw and elbow fitting.
SERVICING INSTRUCTIONS (continued) REPLACE CONTROLLER Disconnect brewer from electric power. Remove top panel IMPORTANT: The two keypad ribbon cables connectors are not polarized and can easily be installed in the wrong position. Be sure to mark the ribbon cable connectors for orientation. Note location of wire connections. Be sure to mark the two keypad ribbon cables as to orientation. Disconnect wiring from controller. Remove four nuts holding controller to cabinet. Fig.
SERVICING INSTRUCTIONS (continued) CAUTION: PROCEDURE: Delime the Water Tank PRECAUTIONS: Disconnect brewer from electric power. Allow brewer to cool. FREQUENCY: As required (Brewer slow to heat) TOOLS: Deliming Solution Protective Gloves, Goggles & Apron Mild Detergent, Clean Soft Cloth or Sponge Bristle Brush, Bottle Brush Large Sink (or other appropriate work area) 1. Disconnect brewer from electric power.
EXPLODED VIEW & PARTS LIST CABINET COMPONENTS 20
EXPLODED VIEW & PARTS LIST (continued) ITEM PART NO.
EXPLODED VIEW & PARTS LIST BREW TRAY COMPONENTS 22
EXPLODED VIEW & PARTS LIST (continued) ITEM PART NO. DESCRIPTION QTY ITEM PART NO.
EXPLODED VIEW & PARTS LIST (continued) SERVICE PARTS KITS 84427 85218 85219 VALVE ASSEMBLY, COMPLETE INLET FITTING KIT ( Includes cap, fitting, gasket & strainer) INLET STRAINER 24
WIRING DIAGRAM 25
Bloomfield Industries proudly supports CFESA Commercial Food Equipment Service Association Bloomfield Industries, Inc. Division of Carrier Commercial Refrigeration In US and Canada Telephone: 775-689-5700 Fax: 888-492-2783 Fax: 800-356-5142 (for orders only) website: www.wellsbloomfield.