User guide

5
Set Your Billing Rates
7
NOTE: If you need to reconfigure your Display Unit after your energy supplier has
changed your rates, perform a Factory (Hard) Reset as described in your User Guide and
start from Step 6 - Configure Your Display Unit.
REMEMBER: To “Enter” a value, press
or
until the correct value is displayed, then
press PROG/SYNC.
Single Flat Rate
1. The RATE and TIER 1 indicators are displayed and the default rate is
flashing. Enter your electricity rate.
2. The THRESHOLD and TIER 1 indicators are now displayed and the
default threshold value is flashing. Press
until a series of dashes is
displayed.
3. Press PROG/SYNC. Your Display Unit exits Configuration Mode.
4. Go to Step 8 - Prepare your Sensor Unit.
NOTE: The next time you change your rates, the TIER 1 indicator is not displayed.
It will only reappear if your enter a value to change the threshold.
Tiered Rates
1. The RATE and TIER 1 indicators are displayed and the default rate is
flashing. Enter your first electricity rate.
2. The THRESHOLD and TIER 1 indicators are now displayed and the
default threshold value is flashing. Enter your (first) threshold
3. The RATE and TIER 2 indicators are now displayed. Enter your
second rate.
4. The THRESHOLD and TIER 2 indicators are displayed and the default
value for the second threshold is flashing. Do one of the following:
s
If you have no more rates to enter, press
until a series of dashes
is displayed.
s
Enter your second threshold and repeat steps 1 and 2 until you
have entered all your rates and thresholds. After your have entered
your last rate, press
until a series of dashes is displayed.
5. Press PROG/SYNC. Your Display Unit exits Configuration Mode.
NOTE: The Display Unit automatically exits Configuration Mode as soon as you enter
a 6th rate.
6. Go to Step 8 - Prepare your Sensor Unit.
Time-based (2 and 3 rates)
1. All the day of the week segments are displayed, with the
SAT and SUN segments flashing. This means that in the
current setting, higher rates are not applied on weekends.
If you do not pay higher rates on weekends, go to step
2 below. If you do pay higher rates on weekends, press
either
or
to make the SAT and SUN display solid
like the other day segments, then press PROG/SYNC.
2. Enter your OFF PEAK RATE.
3. If required, enter your MID PEAK RATE.
4. Enter your ON PEAK RATE.
5. Number “1” is displayed above the clock,
indicating the 1st time slot.
Enter the HOURS when your 1st time slot starts.
Next, enter the MINUTES when your 1st time slot starts.
6. Enter the RATE TYPE of your 1st time slot.
7. Number “2” is now displayed above the clock, indicating
the 2nd time slot. Repeat steps 5 and 6 for all your time slots.
When you are done, press PROG/SYNC for 3 seconds to exit
Configuration mode. Also, note that the Display Unit exits
Configuration mode automatically as soon as you finish entering
the 6th time slot.
TIER
¢/kWh
RATE
TIER
¢/kWh
RATE
TIER
kWh
THRESHOLD
TIER
kWh
THRESHOLD
TIER
kWh
THRESHOLD
TIER
¢/kWh
RATE
TIER
kWh
THRESHOLD
TIER
¢/kWh
THRESHOLD
OFF-PEAK
¢/kWh
PM
º
MID-PEAK
¢/kWh
PM
º
ON-PEAK
¢/kWh
PM
º
3-PEAK
AM
º
3-PEAK
AM
º
OFF-PEAK
AM
º
3-PEAK
AM
º
TUE
3-PEAK
SUN MONWED THUFRI
SAT