Specifications
14
Operation
Operation of the Appliance
E43 and E44 Models.
1. Turn ‘ON’ the mains power at the mains supply, ensure that the Temperature Cut-Out Reset
Switch has been reset (which is located behind the front access door, one for each tank on
twin tank fryers E44 and E44E).
2. Turn ‘ON’ the Mains isolator switch which is located behind the front access door. The Clear
neon indicator will illuminate to indicate that there is mains power to the fryer.
3. Set the tank control thermostat to the temperature required. The Orange neon indicator will
illuminate to indicate that a temperature has been set.
4. When the tank reaches the set temperature, the Orange neon will extinguish to indicate that
the fryer is up to the correct temperature.
5. To turn ‘OFF’ the fryer, turn the tank control thermostat to the ‘OFF’ position.
6. Open the front access door and turn the Temperature Cut-Out Reset Switch to the ‘OFF’
position.
7. Turn ‘OFF’ the mains power at the mains supply.
E43E and E44E Models.
NOTE: For Models E43E and E44E Controller Programming details refer to the ‘Controller
Programming’ section at the rear of this manual.
Power-Up Mode:
1. With the mains power turned on at the mains supply, the appliance will automatically enter
the ‘OFF’ Mode. The display and alarm buzzer will remain ‘OFF’.
2. To turn the appliance ‘ON’, depress and release the ‘ON' / 'OFF’ key on the control panel.
3. The control panel will display ‘CY’ and within 10 seconds of being turned ‘ON’ the heat
indicator (the dot to the left of the ‘CY’) will indicate that the element is now ‘ON’.
Melt Cycle Mode:
NOTE: The only time that the appliance can enter the Melt Cycle, is immediately after
“Power-Up”.
1. The control panel will display ’CY’ and perform the programmed ‘Melt Cycle’ (Either ‘L’ or ‘S’
with the ‘ON' / 'OFF’ times shown in the 'Programmable Default Settings' section.
2. There is a minimum Melt Cycle time of 10 minutes.
3. After the appliance has been in the Melt Cycle for 10 minutes and the cooking medium
temperature is above the melt temperature, the system will exit the Melt Cycle.
4. If the Melt Cycle is programmed to Override (O), then the appliance will not perform the Melt
Cycle and will go directly to the heat cycle and display ‘HEAt’ on the display.
WARNING:
G
REAT CARE MUST BE TAKEN BY THE OPERATOR TO USE THE FRYER SAFELY TO GUARD AGAINST THE RISK OF
INJURY AND FIRE.
• DO NOT
LEAVE THE FRYER UNATTENDED DURING OPERATION.
• DO NOT
REPLENISH THE OIL (FRYING MEDIUM) IN THE FRYER WHEN THE FRYER IS HOT.
• DO NOT
OVER FILL THE OIL (FRYING MEDIUM) IN THE FRYER ABOVE THE TOP LEVEL MARK.
• DO NOT
ALLOW THE OIL (FRYING MEDIUM) IN THE FRYER TO FALL BELOW THE LOWER LEVEL MARK.
• DO NOT
ALLOW THE OIL (FRYING MEDIUM) IN THE FRYER TO OVERHEAT.
• DO NOT
INTRODUCE WET FOOD OR WATER INTO THE HOT OIL (FRYING MEDIUM).
• DO NOT
USE FLAMMIBLE SOLVENTS AND CLEANING AIDS ON OR IN CLOSE PROXIMITY TO THE FRYER
WHILST THE FRYER IS STILL HOT.