Electric Salamanders E91 Service Manual Blue Seal Evolution Series Electric Salamander Revision 1/ © Moffat Ltd, January 2007
WARNING: ALL INSTALLATION AND SERVICE REPAIR WORK MUST BE CARRIED OUT BY QUALIFIED PERSONS ONLY. IMPORTANT: MAKING ALTERATIONS MAY VOID WARRANTIES AND APPROVALS.
Contents This manual is designed to take a more in depth look at the E91 Salamander for the purpose of making the units more understandable to service people. There are settings explained in this manual that should never require to be adjusted, but for completeness and those special cases where these settings are required to change, this manual gives a full explanation as to how, and what effects will result. Section Page Number 1. Specifications............................................................
Blue Seal Evolution Series Electric Salamander Revision 1/ © Moffat Ltd, January 2007
Specifications 1 Model Numbers Covered in this Specification E91 Electric Salamander External Dimensions Front Side Plan 1 Blue Seal Evolution Series Electric Salamander Revision 1/ © Moffat Ltd, January 2007
1 Specifications Electrical Requirements Voltage 220-240Vac, 1P+N+E Power (@ 240Vac) 6.
Installation 2 Installation Requirements NOTE: It is most important that this salamander is installed correctly and that operation is correct before use. Installation shall comply with local electrical, health and safety requirements. Blue Seal Salamanders are designed to provide years of satisfactory service, and correct installation is essential to achieve the best performance, efficiency and trouble-free operation.
2 Installation Clearances This unit must be installed on a non-combustible wall or tailored stand with the following clearances:Combustible Surface Left/Right hand side Non-Combustible Surface 50mm 0mm Rear 50mm 0mm Top Clearance to; Extraction Hood 200mm Ceiling (subject to all local regulation requirements) 300mm Wall Mounting (to non-combustible wall only) NOTE: Only non-combustible materials can be used in close proximity to this appliance. 1.
Installation 2 Electrical Connection WARNING: THIS APPLIANCE MUST BE EARTHED. IF THE SUPPLY CORD IS DAMAGED , IT MUST BE REPLACED BY A SUITABLY QUALIFIED PERSON IN ORDER TO AVOID A HAZARD. When connecting a Blue Seal electric appliance to the main supply, ensure that the following is carried out:• An isolating switch is fitted within 2 m of the appliance, but not on the appliance and in such a position that the user does not have to reach across the cooking surface.
3 Operation 3.1 Description of controls 3.2 The salamander has individual heat controls for the left and right sides. Select the desired heat level and allow a few minutes for the elements to heat up. Racking Racking System The Rack System fitted to the Blue Seal Salamander is self-supporting when withdrawn, to allow easy loading of food. The installation of the rack is dependant on the cooking function required.
Cleaning / Maintenance 4 Caution: ALWAYS TURN OFF THE GAS SUPPLY BEFORE CLEANING. THIS UNIT IS NOT WATER PROOF. DO NOT USE WATER JET SPRAY TO CLEAN INTERIOR OR EXTERIOR OF THIS UNIT. 4.1 Cleaning General Stainless surfaces To achieve the best results, cleaning must be thorough, and all controls and mechanical parts checked and adjusted periodically by a competent serviceman. If any small faults occur, have them attended to promptly. Clean with detergent.
5 Trouble-shooting WARNING: ALL INSTALLATION AND SERVICE REPAIR WORK MUST BE CARRIED OUT BY QUALIFIED PERSONS ONLY. Fault Possible cause The unit does not operate (neither The mains isolating switch on the element works) wall, circuit breaker or fuses are “off” at the power board. One element does not work or, One element coil does not work Indicator light does not illuminate Remedy Turn on. Incorrect electrical supply. Ensure electrical supply correct. Selector switch on unit faulty.
Service Procedures Section 6 Page no. 6.1 Access ....................................................................................................10 6.1.1 6.1.2 Control Panel...........................................................................................................10 Side Panel...............................................................................................................10 6.2 Replacement ................................................................................
6 Service Procedures 6.1 Access 6.2 Replacement 6.1.1 Front panel 6.2.1 Element 1) Remove selector knob by pulling firmly away from control panel. 1) Remove trays and racks from unit. 2) Remove the relevant side panel by removing the two screws located towards the bottom of the applicable side. 2) Undo two screws at the bottom of control panel. Drop control down to access components. 4) Remove wires from the element terminals.
Service Procedures 6 6.2.2 Selector switch 6.2.3 Indicator light 1) Remove the selector knob by pulling firmly away from the control panel. 1) Undo the two screws at the bottom of the control panel. Drop the control panel down to access components. 2) Undo the two screws at the bottom of the control panel. Drop the control panel down to access components. 2) Remove the wires from the rear of the neon. 3) From rear push neon through front of panel rotating clockwise.
7 Accessories Salamander rack (017963) Rack handle (013395) Wall mounting bracket (026096) Side rack (026093) Branding plate (013418) 12 Blue Seal Evolution Series Electric Salamander Revision 1/ © Moffat Ltd, January 2007
Exploded Parts Diagrams 8.1 8 E91 Main Assembly Item Part No.
8 Exploded Parts Diagrams 8.2 E91 Electrical and Rack Assemblies Item Part No. Description 12 026114 ELEMENT SUPPORT WA 13 013920 SALAMANDER ELEMENT SUPPORT SECURING SCREW 14 026088 ELEMENT 3KW DUAL COIL (Ø6.
Circuit Schematics 9 L1 1900W OUTER 1100W P1 P2 2 3 4 1900W OUTER 1100W P1 P2 2 3 4 N E 0 CONTROL SWITCH SETTINGS 1 2 3 OFF 750W 1900W 3000W 15 Blue Seal Evolution Series Electric Salamander Revision 1/ © Moffat Ltd, January 2007
Wiring Diagram P1 2 P2 3 6 P1 P2 2 3 17 7 9 8 4 22 18 16 21 6 21 15 15 22 14 5 5 14 20 1 4 10 19 12 4 2 19 13 20 3 1 10 11 10 16 Blue Seal Evolution Series Electric Salamander Revision 1/ © Moffat Ltd, January 2007
Service Contacts 11 Australia VICTORIA - MOFFAT PTY HEAD OFFICE AND MAIN WAREHOUSE 740 Springvale Road Mulgrave VIC 3170 Spare Parts Department Tel (03) 9518 3888 Fax (03) 9518 3838 Free Call 1800 337 963 Fax (03) 9518 3895 NEW SOUTH WALES - MOFFAT PTY Unit 3/142 James Ruse Drive Rosehill NSW 2142 Spare Parts Tel (02) 8833 4111 Free Call 1800 337 963 Fax (03) 9518 3895 QUEENSLAND - MOFFAT PTY 30 Prosperity Place Geebung QLD 4034 Spare Parts Tel (07) 3630 8600 Free Call 1800 337 963 Fax (03) 9518 3895
11 Service Contacts United Kingdom Utensils Direct 0845 873 6600 www.utensilsdirect.co.
Appendix A : Mounting Hole locations A 80 Mounting hole locations 206 206 80 808 808 Base view 325 325 772 772 Rear view Dimensions shown in millimetres.