G50 / G50-8 GAS RANGE
MANUFACTURED BY Moffat Limited P O Box 10-001 Christchurch New Zealand Ph: (03) 3891-007 Fax: (03) 3891-276 WORLD-WIDE BRANCHES UNITED KINGDOM Blue Seal Units 6-7, Mount Street Business Park Mount Street, Nechells Birmingham B7 5 QU Ph: (121) 327-5575 Fax: (121) 327-9711 UNITED STATES Moffat Inc 3765 Champion Blvd Winston-Salem North Carolina 27115 Ph: (336) 661 0257 Fax: (336) 661 9546 CANADA Lessard Agencies Ltd P O Box 97 Stn D Toronto Ontario M6P3J5 Ph: (416) 766-2764 Fax: (416) 760-0394 NEW ZEALAND Chr
BLUE SEAL GAS RANGE - G50 6 OPEN BURNER GAS RANGE - G50-8 8 OPEN BURNER GAS RANGE CONTENTS PAGE SPECIFICATION 1 INSTALLATION 6 OPERATING INSTRUCTIONS 9 CLEANING 11 MAINTENANCE 11 SERVICING INSTRUCTIONS 12 SPARE PARTS 17 Date Purchased .......................................................Serial No.................................................................. Dealer ...........................................................................................................................
SPECIFICATION GENERAL A heavy duty, general purpose gas range created for compact modular kitchens. It has a high option hob/griddle arrangement. The oven is provided with a piezo ignition lighted constant burning pilot, flame failure device and temperature control thermostat. The hob has Flame Failure Protection for each open burner.
SPECIFICATION Model Input (G20) G50-8D G50-8C G50-8B G50-8A 46.0 kW 41.5 kW 37.0 kW 32.5 kW G50D G50C G50B G50A 36.0 kW 31.5 kW 27.0 kW 22.5 kW Gas Rate (G20) Input (G31) Gas Rate (G31) 4.41 m³/h 3.98 m³/h 3.55 m³/h 3.12 m³/h 45.5 kW 41.0 kW 36.5 kW 32.0 kW 3.25 kg/h 2.93 kg/h 2.60 kg/h 2.29 kg/h 3.45 m³/h 3.02 m³/h 2.59 m³/h 2.16 m³/h 35.5 kW 31.0 kW 26.5 kW 22.0 kW 2.54 kg/h 2.22 kg/h 1.89 kg/h 1.57 kg/h GAS PRESSURE Natural (G20) Propane (G31) Supply Pressure Burner Pressure 20 mbar (8.
SPECIFICATION WEIGHT (NETT) Model G50D Model G50-8D 220kg 295kg GAS CONNECTION Gas connection point 3/4" BSP male thread located 75mm from RH side, 55mm from rear and 610mm from floor.
SPECIFICATION -4-
SPECIFICATION -5-
INSTALLATION It is important that this Range is installed correctly, and that the operation is correct before handing over to the user. THIS APPLIANCE MUST BE INSTALLED TO THE REQUIREMENTS OF THE APPROVED LOCAL INSTALLATION CODE AND LOCAL AUTHORITY REQUIREMENTS, COVERING GAS, FIRE AND HEALTH, AND IN ACCORDANCE WITH THE NATIONAL INSTALLATION CODES: THIS UNIT MUST BE INSTALLED BY A QUALIFIED INSTALLER.
INSTALLATION There are two pressure test points available for measurement of correct appliance operating pressure. Either can be used and they are located; i) On the left hand end of the hob manifold, behind the hob control panel. ii) On the oven thermostatic gas control, behind the oven control panel. Note that the two pressure test points are found on the oven thermostatic gas control, of which the rear test point should be used in this case.
INSTALLATION 4. It is important that adequately sized piping runs directly to the connection joint on the oven, with as few tees and elbows as possible to give maximum supply volume. 5. An accessible shut-off valve must be fitted on the supply line before the connection joint and pressure regulator. 6. A suitable joining compound which resists the breakdown action of LPG must be used on every gas line connection, unless compression fittings are used. 7. Check all connections for leakage.
OPERATING INSTRUCTIONS THIS APPLIANCE IS ONLY FOR PROFESSIONAL USE AND TO BE USED BY QUALIFIED PEOPLE. NOTE: Components having adjustments protected (e.g. paint sealed) by manufacturer are only allowed to be adjusted by an authorised service agent. They are not to be adjusted by the user. If using aluminium foil in the base of the oven, ensure that it does not extend past the oven base tray to ensure correct operation of the oven. A. B. C.
OPERATING INSTRUCTIONS 2. Hold in thermostat knob. 3. With the thermostat knob held in press Piezo button to ignite pilot burner. Repeat until lit. View the lit burner through the inspection hole. 4. Release knob approximately 10 seconds after lighting pilot. 5. Pilot should now remain alight - if not, repeat Steps 2 to 4. 6. The oven temperature can now be set by rotating the control knob anticlockwise to any position from the 1 - 7 markings.
CLEANING & MAINTENANCE CLEANING THE GAS SUPPLY MUST BE OFF DURING CLEANING OR MAINTENANCE. EXTERIOR Clean with detergent. Baked on deposits or discolouration may require a good quality stainless steel cleaner or stainless steel wool. Always apply cleaner when the range is cool and rub in the direction of the "grain". INTERIOR Do not use wire brushes, steel wool or other abrasive materials. Clean the oven regularly with a good quality domestic oven cleaner. Once a week, remove and clean built up grease etc.
SERVICING INSTRUCTIONS NOTE: Components having adjustments protected (e.g. paint sealed) by manufacturer are only allowed to be adjusted by an authorised service agent. They are not to be adjusted by an unauthorised service person. OVEN A. BURNER AIR ADJUSTMENT All gas adjustments should be done by a Qualified Person. The hob open top, griddle and oven burners can all be adjusted to give the most efficient flame.
SERVICING INSTRUCTIONS OVEN BURNER PRESSURE To check oven burner pressure, fit a pressure gauge to the front pressure test point on the oven thermostatic gas control located behind the oven control panel. The oven burner pressures should be measured with the oven burner operating: a) At maximum flow setting (refer oven maximum flow setting). b) At minimum flow setting (refer oven minimum flow setting). To check correct appliance operating pressure and/or supply pressures refer to installation section.
SERVICING INSTRUCTIONS The minimum flow rate adjuster screw is located at the left hand bottom corner on the front of the control. This screw should always be paint sealed. PILOT FLAME SETTING The pilot flame adjusting screw should always be fully open and is factory set and sealed in this state. Field adjustment should not be necessary unless replacing the control.
SERVICING INSTRUCTIONS D. GRIDDLE MAIN BURNER To replace unscrew 3/16" screw at rear of burner and remove. Refit new burner. GAS CONTROL - Servicing To regrease gas control, remove control knobs and control panel. Remove 2 screws holding shaft plate to gas control body and remove control shaft and plate. Note orientation of shaft for correct re-assembly. Using needle nose pliers or similar, pull out gas control spool, again noting orientation.
SERVICING INSTRUCTIONS E. OPEN BURNERS GAS CONTROL - Servicing To regrease gas control follow same procedure as in C for griddle gas controls. GAS CONTROL - Replacement To replace gas control follow same procedure as in C for griddle gas controls. THERMOCOUPLE Should the open burner not remain alight when the control knob is released after ignition, it is likely that the thermo-electric flame failure system has a fault.
SPARE PARTS RANGE G50, G50-8 Part No HOB Description Open Burners 004573 004574 004618 037190 037110 019430 019428 019429 019371 Burner Front Burner Rear Burner Cap Injector (NATURAL) Ø 1.90 mm Injector (PROPANE) Ø 1.10 mm Gas Control Thermocouple - Front M9 x 320 mm UNIFIED Thermocouple - Rear M9 x 850 mm UNIFIED Pressure Test Point Griddle 014105 034210 034130 017800 019215K 018692 018693 019428 016320 018095 016385 016386 016387 Burner Injector (NATURAL) Ø 2.10mm Injector (PROPANE) Ø 1.
SPARE PARTS RANGE G50, G50-8 Part No Description Oven 012248 018691K 020253 032280 032150 019217 018693 019406K 016320 018695 022407 022408 Oven Burner Oven Pilot Oven Thermocouple Oven Burner Injector (NATURAL) Ø 2.80 mm Oven Burner Injector (PROPANE) Ø 1.50 mm Pilot Orifice (PROPANE) Ø 0.23 mm Pilot Orifice (NATURAL) Ø 0.32 mm Gas Control Thermostat Kit Piezo Ignitor Piezo H.T Lead Low fire screw - (PROPANE) 0.95 mm Low fire screw - (NATURAL) 1.