Specifications

9
Clearances
NOTE: Only non-combustible materials can be used in close proximity to this appliance.
* Side clearances can be 50 mm when the adjacent surface is at least 100 mm below the cooking
surface.
Assembly
NOTE:
All Models are delivered completely assembled. No further assembly is required.
This appliance is fitted with adjustable feet to enable the appliance to be positioned
securely and level. This should be carried out on completion of the gas connection. Refer
to the ‘Gas Connection’ section.
Optional Accessories (Refer to Replacement Parts List)
Plinth Kit. For installation details, refer to the instructions supplied with each kit.
1. Check that all the feet (or castors) are securely fitted.
2. Adjust the four feet to make the Range steady and level.
Gas Connection
NOTE: ALL GAS FITTING MUST ONLY BE CARRIED OUT BY AN AUTHORISED PERSON.
1. Blue Seal Ranges do not require an electrical connection, as they function totally on the gas supply
only.
2. It is essential that the gas supply is correct for the appliance to be installed and that adequate
supply pressure and volume are available. The following checks should therefore be made before
installation:-
a. Gas Type the appliance has been supplied for, is shown
on coloured stickers located above the gas connection
point and rating plate. Check that this is correct for the
gas supply the appliance is being installed for. The gas
conversion procedure is detailed in this manual.
b. Supply Pressure required for this appliance is shown in
the “Specifications” section of this manual. Check the gas
supply to ensure adequate supply pressure exists.
c. Input Rate of this appliance is stated on the Rating Plate
and in the ‘Specifications’ section of this manual. The input
rate should be checked against the available gas supply
line capacity. Particular note should be taken if the
appliance is being added to an existing installation.
NOTE: It is important that adequately sized piping runs directly to the connection joint on the
appliance with as few tees and elbows as possible to give maximum supply volume.
3. Fit the gas regulator supplied, into the gas supply line as close to the appliance as possible.
NOTE: The gas pressure regulator provided with this appliance is convertible between Natural Gas
and LPG and is already converted ex-factory to the gas type labelled beside the gas
connection point. The regulator outlet pressure is fixed ex-factory and it is NOT to be
adjusted.
Installation
Fig 1
Rating Plate will be
located in this Area
Combustible Surface Non Combustible Surface
Left/Right hand side 250 mm (*) 0 mm
Rear 100 mm 0 mm