INSTALLATION AND OPERATION MANUAL GAS RANGE STATIC OVEN G505 G506 G508 For use in GB, IE & DK 230104-12
MANUFACTURED BY Moffat Limited Rolleston 7675 New Zealand INTERNATIONAL CONTACTS AUSTRALIA Moffat Pty Limited Web: E.Mail: Main Office: Service: Spares: Customer Service: www.moffat.com.au vsales@moffat.com.au (tel) +61 (03) 9518 3888 (fax) +61 (03) 9518 3838 (tel): 1800 622 216 (tel): 1800 337 963 (tel): 1800 335 315 (fax): 1800 350 281 CANADA Serve Canada Web: E.Mail: Sales: Service: www.servecanada.com info@servecanada.
Contents List Blue Seal Gas Static Oven Range G505 G506 G508 Gas Range Static Oven - 750mm wide. Gas Range Static Oven - 900mm wide. Gas Range Static Oven - 1200mm wide. Introduction .............................................................................................. 2 Specification .............................................................................................. 3 Model Numbers Covered in this Specification General Gas Supply Requirements Gas Connection Dimensions .................
Introduction We are confident that you will be delighted with your BLUE SEAL GAS RANGE STATIC OVEN and it will become a most valued appliance in your commercial kitchen. To ensure you receive the utmost benefit from your new Blue Seal appliance, there are two important things you can do. Firstly: Please read the instruction book carefully and follow directions given. The time taken will be well spent.
Specifications Model Numbers Covered in this Specification G505D[1] Gas Static Oven + 4 Open Burners. G505C[1] Gas Static Oven + 2 Open Burners + 300mm Griddle. G506D[1] Gas Static Oven + 6 Open Burners. G506C[1] Gas Static Oven + 4 Open Burners + 300mm Griddle. G506B[1] Gas Static Oven + 2 Open Burners + 600mm Griddle. G506A Gas Static Oven + 900 mm Griddle. G508D[1] Gas Static Oven + 8 Open Burners + Storage Cabinet.
Specifications Gas Supply Requirements - Australia: Natural Gas LP Gas (Propane) - each Open Burner 28 MJ/hr 28 MJ/hr - each 300mm Griddle Section 21 MJ/hr 21 MJ/hr - Oven 30 MJ/hr 30 MJ/hr 1.13 - 3.40 kPa 2.75 - 4.50 kPa 0.95 kPa 2.6 kPa Input Rate (N.H.G.C.) Supply Pressure Burner Operating Pressure (*) 3 Gas Connection /4” B.S.P.
Specifications - All Other Markets: Natural Gas Town Gas (**) 28MJ/hr 28MJ/hr - each 300mm Griddle Section 21MJ/hr 21MJ/hr - Oven 30 MJ/hr 30 MJ/hr 1.13 - 3.40kPa 0.75 - 1.50kPa 0.95kPa 0.63 Pa Input Rate (N.H.G.C.) - each Open Burner Supply Pressure Burner Operating Pressure (*) Gas Connection See ‘Gas Connection’ information overleaf LP Gas (Propane) Butane 28MJ/hr 28MJ/hr - each 300mm Griddle Section 21MJ/hr 21MJ/hr - Oven 30 MJ/hr 30 MJ/hr 2.75 - 4.50kPa 2.75 - 4.50kPa 2.
Dimensions G505 Cook Top Options G505C G505D 6
Dimensions G506 Cook Top Options G506D G506C G506B G506A 7
Dimensions G508 Cook Top Options G508D G508C G508B G508A 8
Installation Installation Requirements NOTE: It is most important that this appliance is installed correctly and that operation is correct before use. Installation shall comply with local gas and health and safety requirements. This appliance shall be installed with sufficient ventilation to prevent occurrence of unacceptable concentrations of health harmful substances in room, appliance is installed in.
Installation Clearances NOTE: Only non-combustible materials can be used in close proximity to this appliance. Left / Right hand side Rear Combustible Surface 250mm (*) 100mm Non Combustible Surface 0mm 0mm * Side clearances can be 50mm when adjacent surface is at least 100mm below cooking surface. Assembly Caution This appliance is for professional use and is only to be used by qualified persons.
Installation NOTE: Gas pressure regulator provided with this appliance is convertible between Natural Gas and LPG as per ‘Gas Conversion Section’ in this manual. Ensure regulator is converted to correct gas type that appliance will operate on. Regulator outlet pressure is fixed ex-factory for gas type that regulator is converted to and it is NOT to be adjusted. Regulator connections are 3/4" BSP female. Connection to the appliance is 3/4" BSP male.
Operation Operation Guide Caution This appliance is for professional use and is only to be used by qualified persons. Only authorised service persons are to carry out installation, servicing or gas conversion operations. Components having adjustments protected (e.g. paint sealed) manufacturer should not be adjusted by the user / operator. 1. 2. by the Blue Seal appliances have been designed to provide simplicity of operation and 100% safety protection.
Operation NOTE: Pan Size - The maximum pan size to be used is 38cm and the minimum size is 12cm, to ensure satisfactory combustion and pan stability. Open Burners ('F' - Flame Failure Option) Lighting the Open Burners Flame Failure Protection is incorporated for each burner by way of a thermo-electric system which will shut off gas supply to that burner in the event that burner goes out, so that un-burnt gas is not expelled. a.
Operation Griddle Lighting the Griddle a. Depress gas control knob and rotate anti-clockwise to ‘PILOT’ position. b. Hold gas control knob depressed, press piezo ignition button to ignite pilot burner. Repeat Items 1 to 2 until pilot is lit. c. Release gas control knob approximately 10-20 seconds after lighting pilot. d. Pilot should now remain alight - if not, repeat Steps (b. to (c. above. e. To select ‘Full Flame’, depress and rotate gas control knob anti-clockwise to ‘HIGH’ position. f.
Operation Lighting the Oven Main Burner 1. 2. 3. Ensure that pilot burner is alight. Rotate thermostat control knob anti-clockwise to desired temperature marked on knob. Main burner will now ignite automatically, from pilot burner.
Cleaning and Maintenance Before Commencing Cleaning Caution Always turn off the gas / electrical supply before cleaning the appliance. This appliance is not water proof. Do not use water jet spray to clean interior or exterior of this appliance. NOTE: Allow appliance to cool before commencing cleaning. DO NOT use abrasive or strong caustic detergents as they could corrode or damage the Cooktop. Ensure that any detergent or cleaning material has been completely removed after each cleaning.
Cleaning and Maintenance Open Burner Cleaning Griddle Plate Cleaning 1. Remove pot stands, burner caps, burner bowls and pot stand supports from top of cooktop. Wash with hot soapy water, using a soft bristled brush. Dry thoroughly with a dry cloth. Any baked-on deposits can be scraped off using a scraper tool. It is recommended that a flat blade scraper is used to clean the griddle surface, these are not supplied with griddle but may be purchased separately.
Cleaning and Maintenance Oven Interior Cleaning 1. Do not use wire brushes, steel wool or other abrasive materials to clean oven interior. 2. Clean oven regularly with a good quality domestic oven cleaner. 3. Weekly - Remove and clean any built up of grease etc. from oven racks and bottom spill cover. 4. Dry oven thoroughly with a dry cloth and polish with a soft dry cloth. Stainless Steel Surfaces 1. Clean stainless steel surfaces with hot soapy water and a soft bristled brush. 2.
Fault Finding This section provides an easy reference guide to more common problems that may occur during operation of your appliance. The fault finding guide in this section is intended to help you correct, or at least accurately diagnose problems with your equipment. Although this section covers most common problems reported, you may encounter a problem not covered in this section.
Gas Conversion and Specifications Conversion Procedure Caution Ensure that the Appliance is isolated from the gas supply before commencing servicing. NOTE: These conversions should only be carried out by qualified persons. All connections must be checked for leaks before re-commissioning the appliance. Adjustment of components that have adjustments / settings sealed (e.g. paint sealed) can only be adjusted in accordance with the re-commissioning this appliance.
Gas Conversion and Specifications Piezo Igniter Griddle 1. Carry out the following:- Pilot Supply Tube Remove griddle plate section and heat shield. Remove main burner. Disconnect piezo igniter from mounting bracket. (For access purposes). Pilot Burner Disconnect pilot supply tube from pilot burner to access pilot injector. 2. With Main Burner removed, ensure aeration gap is adjusted for type of gas being used as shown in ‘Gas Specifications Tables’ at rear of this section. 3.
Gas Conversion and Specifications Static Oven 1. Pilot Burner Carry out the following:- Piezo Igniter Remove lower lintel at front of oven. Thermocouple Open oven door and remove sole plate(s). Remove main burner. Main Burner Remove thermocouple and piezo igniter from mounting bracket. (For access purposes). Disconnect pilot supply tube from pilot burner to access pilot injector. Main Burner Injector 2.
Gas Conversion and Specifications Gas Regulator NOTE, Pin rotated for Natural Gas - NAT Gas / LPG / Butane Only. NOTE: Gas regulator supplied is convertible between Natural Gas and LP Gas, but it’s outlet pressure is fixed ex-factory and is NOT to be adjusted. NOTE, Pin rotated for LPG - Town Gas Only. 1. 2. 3. Remove slotted cap from regulator. Turn ‘On’ gas supply and appliance. Adjust pressure adjusting screw to achieve correct burner operating pressure.
Gas Conversion and Specifications Gas Specifications - Australia: Open Burner Griddle Oven Main Burner Injectors Pilot Burner ('PF' Option Only) Main Burner Pilot Burner Burner Aeration Setting Main Burner Pilot Burner Low Fire Burner Aeration Setting Supply Pressure Burner Operating Pressure (*) Natural Gas LP Gas (Propane) Ø 2.45mm 0.30 Ø 2.10mm 0.35 Fully Open Ø 2.60mm 0.35 Ø 1.5mm Fully Open 1.13 - 3.40 kPa 0.95 kPa Ø 1.50mm 0.20 Ø 1.30mm 0.23 Fully Open Ø 1.60mm 0.23 Ø 0.95mm Fully Open 2.
Gas Conversion and Specifications - UK Only: Category: Flue Type: Open Burner II2H3P (20, 37). A1. Natural Gas (G20) Propane (G31) Ø 2.30mm Ø 1.40mm Main Burner Injectors Pilot Burner ('PF' Option Only) Main Burner Griddle Pilot Burner Burner Aeration Setting Main Burner Pilot Burner Oven Low Fire Burner Aeration Setting Supply Pressure Burner Operating Pressure (*) 0.30 0.20 Ø 2.10mm 0.35 Fully Open Ø 2.60mm 0.35 Ø 1.5mm Fully Open 20 mbar 9.9 mbar Ø 1.30mm 0.23 Fully Open Ø 1.60mm 0.23 Ø 0.
Gas Conversion and Specifications - All Other Markets: Open Burner Natural Gas Town Gas (**) Ø 2.45mm Ø 4.50mm 0.30 0.60 Ø 2.10mm Ø 3.40mm Main Burner Pilot Burner ('PF' Option Only) Main Burner Griddle Pilot Burner 0.35 0.60 Fully open Fully open Main Burner Ø 2.6mm Ø 5.0mm Pilot Burner 0.35 0.60 Low Fire Ø 1.5mm Ø 2.50mm Burner Aeration Setting Fully Open Fully Open 1.13 - 3-4 kPa 0.75 - 1.50 kPa 0.95 kPa 0.
Replacement Parts Replacement Parts List IMPORTANT: Only genuine authorized replacement parts should be used for servicing and repair of this appliance. Instructions supplied with parts should be followed when replacing components. For further information and servicing instructions, contact your nearest authorized service branch (contact details are as shown on reverse of front cover of this manual). When ordering replacement parts, please quote part number and description as listed below.
Replacement Parts Oven 022446 018691K 020253 018743 032260 032160 032145 032500 026488 019217 018067 Oven Burner. Oven Pilot. Oven Thermocouple. Thermocouple Spacer. Oven Burner Injector Oven Burner Injector Oven Burner Injector Oven Burner Injector Pilot Injector Pilot Injector Pilot Injector (Nat Gas) (LPG) (Butane) (Town Gas) (Nat. Gas) (LPG / Butane) (Town Gas) Ø 2.60mm. Ø 1.60mm. Ø 1.45mm. Ø 5.00mm. 0.35. 0.23. 0.60. 228703 228836 022408 022407 232312 Thermostat / Gas Control Kit.
Gas Conversion and Specifications Gas Regulators Gas Type Gas Regulators Description Part No. Nat. Gas LPG Butane 228531 ¾” BSP F/F Convertible. Town Gas 230185 ¾” BSP F/F Adjustable. Gas Conversion Kits 'PF' Models 'F' Models Models Gas Type to Convert to Nat. Gas LPG Butane Town Gas Nat.