Specifications

Installation
11
NOTE: Gas pressure regulator provided with this appliance is convertible between Natural Gas and
LPG as per ‘Gas Conversion Section’ in this manual.
Ensure regulator is converted to correct gas type that appliance will operate on.
Regulator outlet pressure is fixed ex-factory for gas type that regulator is converted to and it
is NOT to be adjusted.
Regulator connections are
3
/
4
" BSP female.
Connection to the appliance is
3
/
4
" BSP male.
(Refer to ‘Specifications’ section for gas supply location dimensions).
NOTE: A Manual Isolation Valve must be fitted to the individual appliance supply line.
4. Correctly locate appliance into its final operating position and using a spirit level, adjust legs so that
appliance is level and at correct height.
5. Connect gas supply to appliance. A suitable joining compound which resists breakdown action of
LPG must be used on every gas line connection, unless compression fittings are used.
6. Check all gas connections for leakages using soapy water or other gas detecting equipment.
7. Check gas operating pressure is as shown in ‘Specifications’ section.
NOTE: Operating pressure is to be measured
at manifold test point and with 2
burners operating at ‘High Flame’
setting.
8. Verify operating pressure remains correct.
Commissioning
1. Before leaving new installation;
a. Check following functions in accordance with operating instructions specified in ‘Operation’
section of this manual.
 Lighting the Griddle.
 Lighting the Open Burners (F - Flame Failure Option).
 Lighting the Open Burners (PF - Pilot and Flame Failure Option).
 Check the Low Fire burner operation.
 Light the Oven Pilot and Main Burners.
 Check the Oven Main Burner Thermostat operation.
 Turning the Oven to ‘Stand-By’ Mode.
 Oven ‘Shut Down’.
b. Ensure operator has been instructed in areas of correct lighting, operation, and shutdown
procedure for appliance.
2. This manual must be kept by the owner for future reference, and a record of
Date of Purchase,
Date of Installation
and
Serial Number of Appliance
recorded and kept with this manual.
(These details can be found on Rating Plate attached to bottom right hand corner of
bottom sill. Refer to ‘Gas Connection’ section).
NOTE: If it is not possible to get appliance to operate correctly, shut off gas supply and contact
supplier of this appliance.
Manifold
Test Point
Fig 2
DO NOT USE A NAKED FLAME TO CHECK FOR GAS LEAKAGES.
Warning