Specifications

28
Gas Conversion and Specifications
Gas Specifications
(*) NOTE:
The burner operating pressure is to be measured at the manifold test point with two
burners operating at the 'High Flame' setting.
NAT, LPG & Butane Only - The operating pressure is ex-factory set and is not to be
adjusted, apart from when converting between gasses, if required.
TOWN GAS Only - The burner operating pressure is to be adjusted using the adjustable
gas regulator supplied.
Refer to the ‘Gas Conversion and Specifications' section of this manual for further details.
Natural Gas LPG Butane Town Gas
Open Burner
Main Burner
Ø 2.45mm Ø 1.50mm Ø 1.40mm Ø 4.50mm
Pilot Burner
('PF' Models only)
0.30 0.20 0.20 0.60
Griddle
Main Burner
Ø 2.10mm Ø 1.30mm Ø 1.20mm Ø 3.40mm
Pilot Burner
0.35 0.23 0.23 0.60
Burner Aeration Setting
Fully open Fully open Fully open
Supply Pressure
1.13 - 3-40 kPa 2.75 - 4.50 kPa 0.75 - 1.50 kPa
Burner Operating Pressure
0.95 kPa (*) 0.63 kPa (*)
Gas Regulator Cap Screw
Adjustable
Regulator
(Adjust to the
Burner
Operating
Pressure
specified)
2.6 kPa (*)