Specifications
28
Gas Conversion and Specifications
Gas Specifications
(*) NOTE:
• The burner operating pressure is to be measured at the manifold test point with two
burners operating at the 'High Flame' setting.
• NAT, LPG & Butane Only - The operating pressure is ex-factory set and is not to be
adjusted, apart from when converting between gasses, if required.
• TOWN GAS Only - The burner operating pressure is to be adjusted using the adjustable
gas regulator supplied.
• Refer to the ‘Gas Conversion and Specifications' section of this manual for further details.
Natural Gas LPG Butane Town Gas
Open Burner
Main Burner
Ø 2.45mm Ø 1.50mm Ø 1.40mm Ø 4.50mm
Pilot Burner
('PF' Models only)
0.30 0.20 0.20 0.60
Griddle
Main Burner
Ø 2.10mm Ø 1.30mm Ø 1.20mm Ø 3.40mm
Pilot Burner
0.35 0.23 0.23 0.60
Burner Aeration Setting
Fully open Fully open Fully open
Supply Pressure
1.13 - 3-40 kPa 2.75 - 4.50 kPa 0.75 - 1.50 kPa
Burner Operating Pressure
0.95 kPa (*) 0.63 kPa (*)
Gas Regulator Cap Screw
Adjustable
Regulator
(Adjust to the
Burner
Operating
Pressure
specified)
2.6 kPa (*)