Specifications

3
Specifications
Model Numbers Covered in this Specification
G512D-[1]-[2] 2 Open Burners.
G512C -[2] 300mm Griddle.
G514D-[1]-[2] 4 Open Burners.
G514C-[1]-[2] 2 Open Burners + 300mm Griddle.
G514B -[2] 600mm Griddle.
G516D-[1]-[2] 6 Open Burners.
G516C-[1]-[2] 4 Open Burners + 300mm Griddle.
G516B-[1]-[2] 2 Open Burners + 600mm Griddle.
G516A -[2] 900mm Griddle.
G518D-[1]-[2] 8 Open Burners.
G518C-[1]-[2] 6 Open Burners + 300mm Griddle.
G518B-[1]-[2] 4 Open Burners + 600mm Griddle.
G518A-[1]-[2] 2 Open Burners + 900mm Griddle.
[1] - Open Burner Options;
F - With Flame Failure Protection.
PF - With Pilot and Flame Failure Protection.
[2] - Base Stand Options;
B - Bench Mount.
CB - Cabinet Base (excluding G512 series).
LS - Leg Stand (excluding G512 series).
RB - Refrigerated Base (G516 and G518 series only).
General
A heavy duty, high efficiency Cooktop for modular kitchens. It has a high option Cooktop / Griddle
arrangement and is available either on industrial adjustable feet or on robust rollers. Griddle options
with 4 models of base unit available (except G512 model). Fitted with either 'Individual Flame
Failure' (F) or 'Pilot and Flame Failure' (PF) option for each open burner. Griddles are fitted with
pilot, flame failure and piezo ignition as standard. Easy clean stainless steel external finish.
Gas Supply Requirements
(*) NOTE:
The burner operating pressure is to be measured at the manifold test point with two
burners operating at the 'High Flame' setting.
NAT, LPG & Butane Only - The operating pressure is ex-factory set and is not to be
adjusted, apart from when converting between gasses, if required.
TOWN GAS Only - The burner operating pressure is to be adjusted using the Town Gas
adjustable gas regulator supplied.
Refer to the ‘Gas Conversion and Specifications section of this manual for further details.
Natural Gas LP Gas / Butane Town Gas
Input Rate (N.H.G.C.)
- each Open Burner
28 MJ/hr
(26,540 Btu/hr)
28 MJ/hr
(26,540 Btu/hr)
28 MJ/hr
(26,540 Btu/hr)
- each 300mm Griddle Section
21 MJ/hr
(19,900 Btu/hr)
21 MJ/hr
(19,900 Btu/hr)
21 MJ/hr
(19,900 Btu/hr)
Supply Pressure
1.13 - 3.40 kPa
(4.5” -13.5” w.c.)
2.75 - 4.50 kPa
(11” -18” w.c.)
0.75 - 1.50 kPa
(3” - 6” w.c.)
Burner Operating Pressure
0.95 kPa (*)
(3.7” w.c.)
2.6 kPa (*)
(10.0” w.c.)
0.63 kPa (*)
(2.5” w.c.)
Gas Connection
See ‘Gas Connection’ information overleaf