Service manual

1
Specifications
1
© Moffat Ltd, January 2007
Revision 1/
Blue Seal Evolution Series Gas Griddles
Model Numbers covered in this Specification
GP514 - B Gas Griddle 600mm wide Bench Model.
GP514 - CB Gas Griddle 600mm wide with Cabinet Base.
GP514 - LS Gas Griddle 600mm wide on Leg Stand.
GP516 - B Gas Griddle 900mm wide Bench Model.
GP516 - CB Gas Griddle 900mm wide with Cabinet Base.
GP516 - LS Gas Griddle 900mm wide on Leg Stand.
GP516 - RB Gas Griddle 900mm wide with Refrigerated Base.
GP518 - B Gas Griddle 1200mm wide Bench Model.
GP518 - CB Gas Griddle 1200mm wide with Cabinet Base.
GP518 - LS Gas Griddle 1200mm wide on Leg Stand.
GP518 - RB Gas Griddle 1200mm wide with Refrigerated Base.
Gas Supply (Non UK models)
Natural Gas LP Gas (Propane)
GP514 GP516 GP518 GP514 GP516 GP518
Input
Rating
53 MJ/hr
(50,234 BTU)
80 MJ/hr
(75,825 BTU)
108 MJ/hr
(102,364 BTU)
53 MJ/hr
(50,234 BTU)
80 MJ/hr
(75,825 BTU)
108 MJ/hr
(102,364 BTU)
Supply
Pressure
1.13 - 3.40 kPa
(4.5” - 13.5” w.c.)
2.75 - 3.40 kPa
(11” - 13.5” w.c.)
Operating
Pressure
0.85 kPa (*)
(3.4” w.c.)
0.90 kPa (*)
(3.6”w.c.)
2.5 kPa (*)
(9.8” w.c.)
Gas
Connection
¾” BSP Male
2.6 kPa (*)
(10.2” w.c.)
Natural Gas (G20) Propane (G31)
GP514 GP516 GP518 GP514 GP516 GP518
Heat Input (nett) 13.3 kW 21 kW 28.5 kW 13.3 kW 21 kW 28.5 kW
Gas Rate (nett) 1.41 m
3
/hr 2.22 m
3
/hr 3.02 m
3
/hr 1.03 kg/hr 1.63 kg/hr 2.21 kg/hr
Supply Pressure 20 mbar 37 mbar
Burner Operating
Pressure
8.5 mbar (*) 8.2 mbar (*)
Gas Connection
3
/
4
” BSP Male
26 mbar (*)
Gas Supply (Non UK models)
* The burner operating pressure is to be measured at the gas control valve outlet test point with one
griddle burner operating at ‘High’ setting. The operating pressure is ex-factory set, through the
appliance regulator and not to be adjusted, apart from when carrying out gas conversion, if required.
(Refer to the ‘Gas Conversion’ section for details).