Specifications
28
Gas Conversion and Specifications
Main Burner Injectors
1. Unscrew and remove the main burner injectors
(12.7 mm A/F) located in front of main burner
venturi openings.
2. Determine the correct injectors for the
corresponding gas from the ‘Gas Specifications
Table’ at the end of this section.
3. Screw in the correct sized injectors. Refer to the
‘Gas Specifications Table’ at the end of this
section.
Pilot Burner Injectors
1. Unscrew the pilot supply tube from the pilot
burner fitted to the mounting bracket and
remove the pilot injector.
NOTE: On appliances fitted with piezo igniter
electrodes, to prevent damage to the
electrode, unscrew and remove the
electrode from the mounting bracket before
unscrewing the pilot supply tube.
2. Determine the correct sized pilot injectors for the
corresponding gas from the table overleaf.
3. Fit the correct sized injector into the pilot burner
and re-connect the gas supply tube to the pilot
burner.
4. Refit the piezo igniter electrode to the mounting
bracket and tighten hand tight.
Gas Controller
NOTE: For Twin Tank Fryers only, the units will be fitted with 2 gas controllers. These controllers
operate independently of each other. The gas regulators and pilot adjustment will need to
be carried out separately for each gas controller.
Main Burner Operating Pressure Adjustment
a. Connect a manometer to the lower test point (Burner Pressure) on the gas control valve located
through the access hole in the control panel.
b. Remove the slotted cap located directly below the main gas control knob on the gas control
valve, this will reveal an operating pressure adjusting screw.
c. Light the main burners and adjust the adjusting screw to obtain the correct burner pressure for
the type of gas being used. Refer to the specification table shown at the end of this section.
d. Refit the slotted cap to the screw adjustment point.
Thermocouple
Thermopile
Piezo Igniter
Pilot Burner
Fig 10
Fig 11
Main Burner
Injector