Specifications
4
Gas Supply Requirements
- Australia / New Zealand:
- UK Only:
NOTE:
(
*
) The burner operating pressure is to be measured at the lower test point (Out) on the gas
control valve located behind the access door and through the access hole in the control
panel, this is to be carried out with all burners operating at the 'High Flame'
setting. Refer to the ‘Gas Conversion and Specification’ Section for further details.
Specifications
Natural Gas (G20) Propane (G31)
Heat Input (nett) 22.5 kW 22.5 kW
Gas Rate 1.75 kg/hr
Supply Pressure 20 mbar 37 mbar
Burner Operating Pressure 9.8 mbar (*) 25 mbar (*)
Gas Connection
3
/
4
” BSP Male
2.26 m
3
/hr
Natural Gas LP Gas (Propane)
Input Rating 90 MJ/hr 90 MJ/hr
(N.H.G.C.) (85,300 Btu/hr)
(85,300 Btu/hr)
Supply Pressure
1.13 - 2.00 kPa 2.75 - 3.00 kPa
(4.5” - 8.0” w.c.) (11” - 12” w.c.)
Burner Operating Pressure
0.98 kPa (*) 2.50 kPa (*)
(3.9” w.c.) (10.0” w.c.)
Gas Connection ¾” BSP Male