Blue Sky Energy – IPN-ProRemote
7
SETUP Menu
From Advanced Display menu
To Battery Charge Parameters menu
if selected.
FIGURE 4
SET BAT AMP-HRS
220AH SEL
Total battery amp-hours at 25°C, 20hr rate.
SET CHG EFICENCY
94% SEL
SET CHGEFCY MODE
AUTO ADJUST SEL
SET SELF-DISCHG
12%/MONTH SEL
Self discharge rate in percent per month at 25°C.
SET AUX OUT MODE
BAT VOLTS SEL
Sets IPN Master charge controller “load control” mode to be based on battery
VOLTS or battery AMP-HOURS. Setting units (V or AH) in setting screens change
based on present mode setting.
--------------
Note:
Be certain to set voltage settings even if using amp-hour control as the
charge controller will default to voltage control if battery amp-hours are
unavailable.
SET AUX OUT OFF
<
11.5V SEL
SET BAT CHARGE
PARAMETERS SEL
SET AUX OUT ON
>
12.6V SEL
SET BACK-LIGHT
AUTO SEL
Enables, disables and sets ON time for lighting control mode. Lighting control
mode is disabled if BOTH Post-Dusk and Pre-Dawn timers are set to DISABLED
(<0.5 hrs). Lighting control mode is enabled if EITHER Post-Dusk or Pre-Dawn
timers are set to a time value. See charge controller operators manual.
RESTORE DEFAULT
SETINGS SET
Corrects for “zero offset” in net battery current display.
--------------
CAUTION:
Be certain shunt signal is a true zero before performing this function or
inaccurate battery current & amp-hour readings will result. See Resetting Current
Shunt Zero section of manual before proceeding!
With charge efficiency set to 94%, battery is expected to retain 94 amp-hours for
each 100 amp-hours of charge. With charge efficiency mode set to FIXED, charge
efficiency value remains as set. If set to AUTO ADJUST it automatically adjusts
based on actual charge efficiency to continuously improve remaining battery
capacity accuracy.
SET MAXIMUM BAT
VOLTS 15.5V SEL
Maximum charge voltage setpoint limit regardless of other settings or temperature
compensation.
RESET CURRENT
SHUNT ZERO SET
Restores all factory default settings in the IPN-ProRemote and charge controllers,
except for auxiliary output settings in slave controllers. Only the Master’s auxiliary
output settings are available over the IPN network and are restored.
POST-DUSK LIGHTS
ON 2.5 HRS SEL
PRE-DAWN LIGHTS
DISABLED SEL
Sets display backlight to ON, OFF or AUTO. In AUTO, backlight remains ON for
one minute following last key press.