Owner's manual

Blue Sky Energy – Universal Communication Module
19
3) Force Single Coil (0x05)
Query Packet:
Slave address | Function code 0x05 | MSB coil address | LSB coil address |MSB force data, don’t care |
LSB force data, don’t care | LSB CRC | MSB CRC
Response Packet:
Slave address | Function code 0x05 | MSB coil address | LSB coil address |MSB force data, don’t care |
LSB force data, don’t care | LSB CRC | MSB CRC
FORCE COILS
PDU ADDRESS LOGICAL COIL # DESCRIPTION
0x0013 20 Start Equalize
0x0014 21 Stop Equalize
0x0015 22 Clear Max. Battery Volts Detected
0x0016 23 Clear Min. Battery Volts Detected
0x0017 24 Clear Total Charge Amp-Hours
0x0018 25 Clear Lifetime Battery Discharge Amp-Hours
0x0019 26 Set Charge Efficiency to Auto Mode
0x001A 27 Set Charge Efficiency to Fixed Mode
0x001B 28 Set Aux. Out Mode to Volts
0x001C 29 Set Aux. Out Mode to Amp-Hours
0x001D 30 Restore Charge Controller Defaults
TABLE 6
UCM SETUP PARAMETERS
¾ The UCM has various setup parameters all of which are preconfigured at the factory.
A
ll setting are stored either in nonvolatile
memory, DIP switches or jumpers such that all settings are retained following a loss of power.
As Shipped Factory Default Settings
Basic TCP/IP Communication FTP File Transfer
IPv4 IP Address ......................................... 192.168.1.235 Server address ......................................................... blank
Subnet Mask .............................................. 255.255.255.0 User Name ............................................................... blank
Gateway IP Address ................................. 192.168.1.1 Password ................................................................... blank
IP-A (force use of comm defaults) ............ off Hours Between Uploads .......................................... Disabled
Datalogging UCM logon
Hours in Log Period ................................... Disabled Password................................................................... admin
MODBUS
Address / Unit Identifier ............................. 1 (AD0 AD7 all off) RS-485 Duplex Mode ............................................... Half Duplex
RS485 DataBits/Parity/StopBits ............... 8/Even/1 (Baud1/Parity off) RS-495 Baud rate ..................................................... 19.2K (baud0 off)
Misc.
Location Name Reminder ......................... MY SOLAR SYSTEM
Restoring As Shipped Factory Default Settings
1. Remove UCM power 5. Set all 12 DIP’s shown in Figure 4 to OFF
2. Set DIP’s AD0 AD7 shown in Figure 4 to all ON 6. Install two jumper plugs A-to-A’ and B-to-B’ shown in Figure 4
3. Restore UCM power for 10 seconds, confirm power LED blinking 7. UCM is now restored to As Shipped Factory Default Settings
4. Remove UCM power
)