Owner's manual

Page 14
Sonic-Pro
6.3.1
Logging
Menu
Data logs are stored in the meters internal memory in a space delimited .TXT file that can
easily be copied to a removable USB flash drive located on the main circuit board. Each log
file includes the date and time, the flow rate (FR) and the flow total (TL). A total of 191,800
logs can be stored.
2013/12/29 09:15:00 FR 0.0000 TL 0.00
The Log Interval determines the number of seconds from 1 - 999,999 that the meter will wait
between logs.
If a value is entered into Rate Set Point 1, a new log will be generated every 60 seconds
while the measured rate of flow is greater than the configured value.
If a value is entered into Rate Set Point 2, a new log will be generated every 60 seconds
while the measured rate of flow is less than the configured value.
If a value is entered into any Tot. Set Point (1, 2, 3, 4 or 5), a new log will be generated
when the total accumulated flow value is equal to the configured value.
To access the log entries, you must copy the logs onto a USB flash drive and transfer the file
to a computer for reading. To copy all of the log entries, open the enclosure and insert a USB
flash drive. Highlight Copy Logs press either right arrow u or ENTER. When copying logs,
all of the logs must be copied. You may not copy only selected logs.
To delete ALL of the log entries, highlight Delete Logs then press either right arrow u or
ENTER. You may not delete only selected logs. All logs must be deleted.
Logging
Log Interval(s)
0.0000
Enter Value
Copy Logs
Delete Logs
Rate Set Point 1
0.0000
Enter Value
0.0000
Enter Value
Tot. Set Point 1
0.0000
Enter Value
0.0000
Enter Value
Rate Set Point 2
Tot. Set Point 2
0.0000
Enter Value
0.0000
Enter Value
Tot. Set Point 5
0.0000
Enter Value
Tot. Set Point 3
Tot. Set Point 4
Page 13
Sonic-Pro
6.3
Configure the
SPU Meter
Settings
In the Meter Settings menu, the data logging functions and the display features can be
configured.
Meter Settings
Logging
Log Interval(s)
0.0000
Enter Value
Copy Logs
Delete Logs
Display
Flow Rate Volume Units
Ounces
U.S. Gallons
U.S. Barrels Liq.
U.S. Barrels Oil
Cubic Feet
Acre Feet
Imperial Gallons
Cubic Meters
Liters
Milliliters
FR Custom V/Gal
Time Units
Seconds
Hours
Days
Minutes
Fl. Rate Decimal
0
Enter Value
Totalizer Volume Units
Ounces
U.S. Gallons
U.S. Barrels Liq.
U.S. Barrels Oil
Cubic Feet
Acre Feet
Imperial Gallons
Cubic Meters
Liters
Milliliters
FR Custom V/Gal
Fl. Total Decimal
0
Enter Value
Flow Average(s)
0
Enter Value
Enable Tot. Clear?
Yes
No
Low Fl. Cut-Off
0
Enter Value
High Fl. Cut-Off
999
Enter Value
Scaling Off-set
1.0000
Enter Value
Zero Off-set
Sign
FR Offset
0.0000
Enter Value
Negative
Positive
SOS Fault Window
10
Enter Value
Rate Set Point 1
0.0000
Enter Value
Sleep Time(s)
0
Enter Value
0.0000
Enter Value
Tot. Set Point 1
0.0000
Enter Value
0.0000
Enter Value
Rate Set Point 2
Tot. Set Point 2
0.0000
Enter Value
0.0000
Enter Value
Tot. Set Point 5
0.0000
Enter Value
Tot. Set Point 3
Tot. Set Point 4
0
Enter Value
0
Enter Value
Industries, Ltd.
Industries, Ltd.
ProSeries
by Blue-White Ind.
d
Industries, Ltd.
Industries, Ltd.
ProSeries
by Blue-White Ind.
d