INSTALLATION
BUILT
-
IN FIREPLACE INSTALLATION
Figure 7 - Rough Opening for Wall
Installation
Figure 5 - Clearance to Combustibles
Figure 6 - Fireplace Clearances
WARNING: Do not allow any
combustible materials to overlap
the rebox front.
WARNING: Do not allow
combustible or noncombustible
materials to cover any necessary
openings like louvered slots.
WARNING: Never modify or
cover the louvered slots on the
front of the rebox.
Built-in installation of this replace involves
installing replace into a framed-in enclosure.
This makes the front of the replace ush
with wall. If installing a built-in mantel above
the replace, you must follow the clearances
shown in Figure 5.
NOTICE: Surface temperatures
of adjacent walls and mantels
become hot during operation.
Walls and mantels above the
replace may become hot to the
touch. If installed properly, these
temperatures meet the require-
ment of the national product
standard. Follow all minimum
clearances shown in this manual
(see Figure 6).
1. Frame in rough opening. Use dimensions
shown in Figure 7 for the rough opening.
If installing in a corner, use dimensions
shown in Figure 8 (page 11) for the rough
opening. The height is 19", which is the
same as the wall opening above.
2. Carefully set replace in front of rough
opening with back of replace inside wall
opening.
3. Attach gas line to replace gas regulator.
See Connecting to Gas Supply, page 12.
4. Check all gas connections for leaks. See
Checking Gas Connections, page 14.
1/4" Clearance to Facia
3/8" Clearance to Sides, Back and Top
15
5
/
8
"
16"
28"
5"
4"
6"
8"
10"
12"
To
Ceiling
Hood Top
Fireplace
Safe Zone
12"
9"
6"
3"
1
1
/
2
"
1
3
/
4
"
Slope
Factor
19
3
/
5
"
26
1
/
8
"
11"
9
1
/
4
"
15
5
/
8
"