Use and Care Manual

www.bluegrassliving.com
172000458-01A
Figure 21 - Burner Patterns
OPERATION
Figure 20 - Pilot
Pilot Burner
Ignitor Electrode
Thermocouple
OFF
Figure 19 - Control Knob in the OFF
Position
LO
OFF
HI
PILOT
IGNITOR
Control
Knob
6. With control knob pressed in, push
down and release ignitor button. This
will light pilot. The pilot is attached to
the front of burner. The pilot can be
seen through the grill. If needed, keep
pressing ignitor button until pilot lights.
Note: If pilot does not stay lit, refer to
Troubleshooting, pages 21 though 23.
Also contact a qualied service technician
or gas supplier for repairs. Until repairs are
made, light pilot with match. To light pilot
with match, see Manual Lighting Procedure.
7. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. If control
knob does not pop up when released,
contact a qualied service technician or
gas supplier for repairs.
Note: If pilot goes out, repeat steps 3
through 7. This heater has a safety inter-
lock system. Wait one (1) minute before
lighting pilot again.
8. Turn control knob counterclockwise
to desired heating level. The main burner
should light. Set control knob to any heat
level between HI and LO.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shuto valve.
MANUAL LIGHTING PROCEDURE
1. Remove lower front panel.
2. Follow steps 1 through 5 under Lighting
Instructions, page 16.
3. With control knob pressed in, strike match.
Hold match to pilot until pilot lights.
THERMOSTAT CONTROL OPERATION
TO TURN OFF GAS TO APPLIANCE
Shutting Off Heater
Turn control knob clockwise to the
OFF position.
Shutting Off Burner Only
(pilot stays lit)
Turn control knob clockwise to the
PILOT position.
The thermostatic control used on these mod-
els dier from standard thermostats. Standard
thermostats simply turn the burner on and o.
The thermostat used on this heater senses
the room temperature. At times the room may
exceed the set temperature. If so, the burner
will shut o. The burner will cycle back on
when room temperature drops below the set
temperature. The control knob can be set to
any comfort level between HI and LO.
4. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob. Follow step 8 under
Lighting Instructions, page 17.
5. Replace lower front panel.