BG952-V Specifications Sheet

Page 1
BG952-V
PRODUCT SPECIFICATIONS
CONFIGURATIONS
Upflow / Horizontal
Downflow
VENTING
2-speed induced draft motor with stainless steel shaft, steel ball
bearings, and fan cooled for long life
Vent materials for Canadian applications must comply with ULC S636
Certified for direct vent (2-pipe) or non-direct (1-pipe) applications
Direct vent refers to a combustion air supply intake pipe installed in
conjunction with flue gas vent pipe.
INSTALLATION FEATURES
Left or right gas and electric entry
Zero step horizontal conversion
Removable floor base (upflow/horizontal units) for bottom return air
All models comply with California's South Coast Air Quality
Management district Low NOx requirements
TWO STAGE VARIABLE SPEED
GAS FURNACE
FORM NO. BG952V-100 (10/2018)
HEAT EXCHANGER DESIGN
Aluminized steel primary heat exchanger with crimped non-
welded construction
AL29-4C Stainless steel secondary heat exchanger
Non-welded crimped S-curve primary heat exchanger design
for maximum durability
BURNERS
Aluminized steel in shot burners for smooth ignition
Isolated burner enclosure for quiet operation
CABINET CONSTRUCTION
Compact 33" height
Standardized widths for easy coil fit
Unitized construction for cabinet integrity
Heat exchanger compartment is insulated to increase
efficiency and reduce sound levels
Baked on pre painted steel cabinet finish
AIR DELIVERY SYSTEM
Efficient ECM variable speed blower motor
Motor features "soft start" and "soft stop" for quiet operation
Active and passive dehumidification feature
Easily removable slide-out blower design
Dynamically balanced blower wheel with resilient
motor mounts for smooth and quiet operation
CONTROLS
Two stage gas valve
Integrated ignition and fan control
System Sentry™ control retains last five (5) fault codes with
push button memory recall, regardless of power interruption
Hot surface ignition system uses silicon nitride ignitor
Control features 120 volt electronic air cleaner and humidifier
terminals
Control circuit is fuse protected
Color coded control wiring
Compatible with single or two stage thermostats for heating.
Two stage thermostat is recommended when installed with
two stage cooling unit.
WARRANTY
10 year limited parts warranty / lifetime heat exchanger warranty
available. See limited warranty document for details.
California Only
If installed in South Coast Air Quality Management District (SCAQMD) only: This
furnace does not meet the SCAQMD Rule
1111
NOx emission limit (14 ng/J), and
thus is subject to a mitigation fee of up to $450. This furnace is not eligible for the
Clean Air Furnace Rebate Program: www.CleanAirFurnaceRebate.com.
If installed in San Joaquin Valley Air Pollution Control District (SJVAPCD) only:
This furnace does not meet the SJVAPCD Rule 4905 NOx emission limit (14 ng/J),
and thus is subject to a mitigation fee of up to $450.

Summary of content (6 pages)