BHP15 Specifications Sheet

15 SEER SPLIT SYSTEM HEAT PUMP
BHP15
Page 4
COOLING PERFORMANCE WITH EVAPORATOR COILS
Outdoor Model
Indoor Model
Cooling
Heating
CFM
Refrigerent Connection
Refirgerent
Line Size
Indoor Expan-
sion Device
Evap. Coil
SEER
EER
AHRI Rated
Capacity BTUH
Sensible
Capacity BTUH
HSPF
47°
17°
Outdoor
Indoor
Btuh
COP
Btuh
COP
Suction
Liquid
Suction
Liquid
Suction
Liquid
Piston
TXV
BHP15L18P-1
BC1P23(A,B)+H4TXV02+45
SEC BLOWER DELAY
14
12
18000
13200
8.2
17000
3.5
10000
2.3
650
3/4
3/8
3/4
3/8
3/4
3/8
N/A
H4TXV01
BC4X23(A,B)+45 SEC
BLOWER DELAY
14
12
18000
13200
8.2
17000
3.5
10000
2.3
650
3/4
3/8
3/4
3/8
3/4
3/8
INC
BHP15L24P-1
BC1P24(A,B)+H4TXV01+TDR
14
11.5
23400
17000
8.2
22000
3.4
14000
2.3
850
3/4
3/8
3/4
3/8
3/4
3/8
H4TXV01
BC1P29(A,B)+H4TXV01+TDR
14
11.5
23400
17000
8.2
22000
3.4
14000
2.3
850
3/4
3/8
3/4
3/8
3/4
3/8
H4TXV01
BC4X24A,B+TDR
14
11.5
23400
17000
8.2
22000
3.4
14000
2.3
850
3/4
3/8
3/4
3/8
3/4
3/8
INC
BC4X29A,B+TDR
14
11.5
23400
17000
8.2
22000
3.4
14000
2.3
850
3/4
3/8
3/4
3/8
3/4
3/8
INC
BHP15L30P-1
BC1P43(B,C)+H4TXV02+TD
R
14
11.5
28000
20300
8.2
25000
3.5
15000
2.5
1050
3/4
3/8
3/4
3/8
3/4
3/8
H4TXV01
BC4X43B+TDR
14
11.5
28000
20300
8.2
25000
3.5
15000
2.5
1050
3/4
3/8
3/4
3/8
3/4
3/8
INC
BHP15L36P-1
BC1P43B+H4TXV02
14
12
34000
25100
8.2
33800
3.5
21800
2.5
1200
7/8
3/8
3/4
3/8
7/8
3/8
H4TXV02
BC1P49C+H4TXV02
14
12
34000
25100
8.2
33800
3.5
21800
2.5
1200
7/8
3/8
3/4
3/8
7/8
3/8
H4TXV02
BC4X43B+TDR
14
12
34000
25100
8.2
33800
3.5
21800
2.5
1200
7/8
3/8
3/4
3/8
7/8
3/8
INC
BC4X49C+TDR
14
12
34000
25100
8.2
33800
3.5
21800
2.5
1200
7/8
3/8
3/4
3/8
7/8
3/8
INC
BHP15L42P-1
BC1P49C+H4TXV02+TDR
14
12
41000
30200
8.2
40000
3.5
27800
2.4
1400
7/8
3/8
3/4
3/8
7/8
3/8
H4TXV02
BC1P62D+H4TXV02+TDR
14
12
41000
30200
8.2
40000
3.5
28800
2.4
1400
7/8
3/8
3/4
3/8
7/8
3/8
H4TXV02
BC4X49C+TDR
14
12
41000
30200
8.2
40000
3.5
27800
2.4
1400
7/8
3/8
3/4
3/8
7/8
3/8
INC
BC4X62D+TDR
14
12
41000
30200
8.2
40000
3.5
28800
2.4
1400
7/8
3/8
3/4
3/8
7/8
3/8
INC
BHP15L48P-1
BC1P49C+H4TXV02+TDR
14
12
47000
34600
8.2
46000
3.4
29600
2.5
1600
7/8
3/8
3/4
3/8
7/8
3/8
H4TXV02
BC1P62D+H4TXV02+TDR
14
12
47000
34600
8.2
46000
3.4
29600
2.5
1600
7/8
3/8
3/4
3/8
7/8
3/8
H4TXV02
BC4X49C+TDR
14
12
47000
34600
8.2
46000
3.4
29600
2.5
1600
7/8
3/8
3/4
3/8
7/8
3/8
INC
BC4X62D+TDR
14
12
47000
34600
8.2
46000
3.4
29600
2.5
1600
7/8
3/8
3/4
3/8
7/8
3/8
INC
BHP15L60P-1
BC1P62C+H4TXV03+TDR
14
12
57000
42100
8.2
55000
3.4
36000
2.5
1900
7/8
3/8
7/8
3/8
1 1/8
3/8
H4TXV03
BC1P62D+H4TXV03+TDR
14
12
57000
42100
8.2
55000
3.4
36000
2.5
1900
7/8
3/8
7/8
3/8
1 1/8
3/8
H4TXV03
BC4X62C+TDR
14
12
57000
42100
8.2
55000
3.4
36000
2.5
1900
7/8
3/8
7/8
3/8
1 1/8
3/8
INC
BC4X62D+TDR
14
12
57000
42100
8.2
55000
3.4
36000
2.5
1900
7/8
3/8
7/8
3/8
1 1/8
3/8
INC
Note:
1
Ce
r
t
i
f
i
e
d
i
n
a
cc
o
r
d
a
n
c
e
w
i
t
h
U
n
i
t
a
r
y
A
i
r
C
o
n
d
i
t
i
o
n
e
r
Ce
r
t
i
f
i
c
a
t
i
o
n
P
r
og
r
a
m
,
w
h
i
c
h
i
s
b
a
s
e
d
o
n A
H
R
I
S
t
a
n
d
a
r
d
2
1
0
/
2
4
0
2
Required to achieve AHRI rating. If NA (Not Applicable) is in the piston column, then TXV is required.
3 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace and AH products
LINE SETS
Outdoor Model
Condenser Refrigerant
Connection
Refrigerant Line Size
Outdoor
Suction
Liquid
Suction
Liquid
BHP15L18P
3/4
3/8
3/4
3/8
BHP15L24P
3/4
3/8
3/4
3/8
BHP15L30P
3/4
3/8
3/4
3/8
BHP15L36P
7/8
3/8
7/8
3/8
BHP15L42P
7/8
3/8
7/8
3/8
BHP15L48P
7/8
3/8
7/8
3/8
BHP15L60P
7/8
3/8
1 1/8
3/8