BHP16 Spec Sheet 1

16 SEER SPLIT SYSTEM HEAT PUMP 4HP16LT
Page 3
Outdoor Model
Indoor
Model
Cooling Heating
CFM
Refrigerant
Connection
Refrigerant
Line
Size
Indoor
Expansion
Device
Outdoor Indoor
Suction
Liquid
Piston
2
TXV
Evaporator
Coil
3
SEER
EER
AHRI Rated
Capacity
1
BTUH
Sensible
Capacity
BTUH
HSPF
47° 17°
Suction
Liquid
Suction
Liquid
Btuh
COP
Btuh
COP
4HP16LT24P-1
E*1P29+TDR+TXV 13.0 11.0 23,000 16,600 7.7 23,000 3.0 14,000 2.0 850 3/4 3/8 3/4 3/8 3/4 3/8
NA
H4TXV01
E*1P36+TDR+TXV 13.0 11.0 23,000 16,600 7.7 23,000 3.0 14,000 2.0 850 3/4 3/8 3/4 3/8 3/4 3/8
4HP16LT36P-1
E*1P36+TDR+TXV 13.0 11.0 35,000 25,400 7.7 36,000 3.0 22,000 2.0 1,310 7/ 8 3/8 3/4 3/8 3/4 3/8
E*1P43+TDR+TXV 13.0 11.0 35,000 25,400 7.7 36,000 3.0 22,000 2.0 1,310 7/8 3/8 3/4 3/8 3/4 3/8
4HP16LT48P-1
E(U,C,M,H)1P49C 13.0 11.0 47,000 33,500 7.7 45,000 3.0 28,000 2.0 1,600 7/8 3/8 7/ 8 3/8 7/ 8 3/8
H4TXV02
E(U,C,M,H)1P62C 13.0 11.0 47,000 33,500 7.7 45,000 3.0 28,000 2.0 1,600 7/ 8 3/8 7/ 8 3/8 7/8 3/8
4HP16LT60P-1
E(U,C,M,H)1P62C 13.0 11.0 59,000 43,000 7.7 59,000 3.3 35,000 2.0 1,920 7/ 8 3/8 7/ 8 3/8 1-1/8 3/8
COOLING PERFORMANCE WITH EVAPORATOR COILS
Note:
1 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240
2 Required to achieve AHRI rating. If NA (Not Applicable) is in the piston column, then TXV is required.
3 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace and AH products.