BHP16 Spec Sheet 1

16 SEER SPLIT SYSTEM HEAT PUMP 4HP16LT
Page 5
COOLING PERFORMANCE WITH AIR HANDLERS AND FURNACES
Outdoor Model
Indoor Model Cooling Heating
CFM
Refrigerant
Connection
Refrig.
Line
Size
Indoor
Expansion
Devise
Outdoor Indoor
Suction
Liquid
Piston
2
TXV
Evaporator
Coils or
Air Handler
3
Furnace
SEER
EER
ARI Rated
Cap.
1
Sensible
Cap.
HSPF
47 17
Suction
Liquid
Suction
Liquid
Btuh
COP
Btuh
COP
4HP16LT36P-2
E(U,C,M,H)1P36B 95G2DF070BV16 15.0 12.0 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/ 8 3/8 3/4 3/8 7/ 8 3/8
NA
H4TXV01
E(U,C,M,H)1P43B 95G2DF070BV16 15.0 12.0 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/8 3/8 7/8 3/8 7/ 8 3/8
E(U,C,M,H)1P36C 95G2DF090CV20 15.0 12.5 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/ 8 3/8 3/4 3/8 7/ 8 3/8
E(U,C,M,H)1P43C 95G2DF090CV20 15.5 12.5 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/ 8 3/8 7/ 8 3/8 7/ 8 3/8
E(U,C,M,H)1P36C 95G2DF110CV20 15.0 12.5 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/8 3/8 3/4 3/8 7/ 8 3/8
E(U,C,M,H)1P43C 95G2DF110CV20 15.5 12.5 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/8 3/8 7/ 8 3/8 7/ 8 3/8
E(U,C,M,H)1P36C 95G1UH090CE16 15.0 12.5 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/ 8 3/8 3/4 3/8 7/ 8 3/8
E(U,C,M,H)1P43C 95G1UH090CE16 15.0 12.5 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/ 8 3/8 7/ 8 3/8 7/ 8 3/8
E(U,C,M,H)1P36B 95G2UH045BV12 15.0 12.5 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/ 8 3/8 3/4 3/8 7/8 3/8
E(U,C,M,H)1P43B 95G2UH045BV12 15.0 12.0 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/ 8 3/8 7/ 8 3/8 7/ 8 3/8
E(U,C,M,H)1P36B 95G2UH070BV12 15.0 12.0 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/8 3/8 3/4 3/8 7/ 8 3/8
E(U,C,M,H)1P43B 95G2UH070BV12 15.0 12.0 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/ 8 3/8 7/ 8 3/8 7/ 8 3/8
E(U,C,M,H)1P36C 95G2UH090CV12 15.0 12.5 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/ 8 3/8 3/4 3/8 7/ 8 3/8
E(U,C,M,H)1P43C 95G2UH090CV12 15.5 12.5 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/ 8 3/8 7/ 8 3/8 7/ 8 3/8
E(U,C,M,H)1P36C 95G2UH090CV20 15.0 12.5 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/ 8 3/8 3/4 3/8 7/ 8 3/8
E(U,C,M,H)1P43C 95G2UH090CV20 15.5 12.5 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/8 3/8 7/ 8 3/8 7/ 8 3/8
4HP16LT48P-2
BCS2M48V00NA1P 16.0 12.5 47,000 33,500 8.5
46,000
3.2 29,000 2.40 1,600 7/8 3/8 7/ 8 3/8 7/ 8 3/8
NA
H4TXV02
E(U,C,H)1P49C EFV16CC 14.5 11.5 46,500 33,100 8.0
46,000
3.0 29,000 2.00 1,600 7/ 8 3/8 7/ 8 3/8 7/ 8 3/8
E(U,C,H)1P62C EFV16CC 14.5 12.0 46,500 33,100 8.0
46,000
3.0 29,000 2.00 1,600 7/ 8 3/8 7/ 8 3/8 7/ 8 3/8
E(U,C,H)1P49C 80G1DF110CE20 14.0 12.0 47,000 33,500 8.5 46,500 3.3 29,000 2.40 1,600 7/ 8 3/8 7/ 8 3/8 7/ 8 3/8
E(U,C,H)1P62C 80G1DF110CE20 14.0 12.0 47,000 33,500 8.5 46,500 3.3 29,000 2.40 1,600 7/ 8 3/8 7/ 8 3/8 7/ 8 3/8
E(U,C,H)1P49C 80G1UH090CE20 14.5 12.0 47,000 33,500 8.5 46,500 3.3 29,000 2.40 1,600 7/ 8 3/8 7/ 8 3/8 7/ 8 3/8
E(U,C,H)1P62C 80G1UH090CE20 14.5 12.0 47,000 33,500 8.5 46,500 3.3 29,000 2.40 1,600 7/ 8 3/8 7/ 8 3/8 7/ 8 3/8
E(U,C,H)1P49C 80G1UH110CE20 14.5 12.0 47,000 33,500 8.5 46,500 3.3 29,000 2.40 1,600 7/ 8 3/8 7/ 8 3/8 7/ 8 3/8
E(U,C,H)1P62C 80G1UH110CE20 14.5 12.0 47,000 33,500 8.5 46,500 3.3 29,000 2.40 1,600 7/ 8 3/8 7/ 8 3/8 7/ 8 3/8
E(U,C,H)1P49C 80G2UH110CV20* 15.0 12.0 47,000 33,500 8.5 46,500 3.3 29,000 2.40 1,600 7/ 8 3/8 7/ 8 3/8 7/8 3/8
E(U,C,H)1P62C 80G2UH110CV20* 15.0 12.0 47,000 33,500 8.5 46,500 3.3 29,000 2.40 1,600 7/ 8 3/8 7/ 8 3/8 7/ 8 3/8
E(U,C,H)1P49C 95G1DF110CE20 14.0 12.0 47,000 33,500 8.5 46,500 3.3 29,000 2.40 1,600 7/ 8 3/8 7/ 8 3/8 7/ 8 3/8
E(U,C,H)1P62C 95G1DF110CE20 14.0 12.0 47,000 33,500 8.5 46,500 3.3 29,000 2.40 1,600 7/ 8 3/8 7/ 8 3/8 7/ 8 3/8
E(U,C,H)1P49C 95G2DF090CV20 14.5 11.5 47,000 33,500 8.5 46,500 3.3 29,000 2.40 1,600 7/ 8 3/8 7/ 8 3/8 7/ 8 3/8
E(U,C,H)1P62C 95G2DF090CV20 15.0 11.5 47,000 33,500 8.5 46,500 3.3 29,000 2.40 1,600 7/ 8 3/8 7/ 8 3/8 7/ 8 3/8
1 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240
2 Required to achieve AHRI rating. If NA (Not Applicable) is in the piston column, then TXV is required.
3 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace and AH products.
Note: