Single Zone 19 SEER Ductless Mini Split Spec Sheet

2
Capacity and
Ratings
BM09Y18
BM12Y19
BM18Y19
BM24Y17
Cooling
Capacity (Btu/Hr)
9000 (3600-
10300)
12000 (3700-
13000)
18000 (4500-
18500)
24000 (6850-
24500)
Input (W)
782
1065
1645
2500
Rated current (A)
6.8
4.5
7.35
11.0
EER (Btu/w)
11.0
11.0
11.0
9.5
SEER (Btu/w)
18.0
19
19
17
Heating
Capacity (Btu/Hr)
9000 (3500-
10900)
Input (W)
925 1025 1700 2200
Rated current (A)
8.1 4.3 7.4 9.6
COP (W/W)
3.11 3.43 3.1 3.2
HSPF4 (Btu/w)
9.5 9.5 10.0 9.5
HSPF5 (Btu/w)
8.0 8 8.0 8.0
Operating Temperature
Range
BM09Y18
BM12Y19
BM18Y19
BM24Y17
Indoor cooling
17
32
17
32
17
32
17
32
Indoor heating
0
30
0
30
0
30
0
30
Indoor cooling
6290
6290
6290
6290
Indoor heating
3286
3286
3286
3286
Outdoor cooling
-15~50
-15~50
-15~50
-15~50
Outdoor heating
-15
30
-15
30
-15
30
-15
30
Outdoor cooling
5122
5122
5122
5122
Outdoor heating
586
586
586
586
Air Flow and
Sound Levels
BM09Y18
BM12Y19
BM18Y19
BM24Y17
Indoor air flow
(Hi/Mi/Lo)
m3/h
525/483/318 550/480/360 765/668/446 1200/1000/765
Indoor air flow
(Hi/Mi/Lo)
CFM
309/285/187 324/282/212 449/97/393/262 706/588/450
Indoor noise
level (Hi/Mi/Lo)
dB(A)
38/32/25 38/32/24 43/35/30.5 48/42.5/34
Outdoor air flow
m3/h
2000 2000 2000 3100
Outdoor air flow
CFM
1176.47 1176 1176 1823
Outdoor noise
level
dB(A)
52 55 57.5 58