Single Zone Concealed Duct Spec Sheet

U-Match Series Hyper Heat Series
Indoor Code
22023011003415 22023011003414
Outdoor Code 22022516000402) 32022016000001)
Indoor Model
BM36MCD BM24MCD
Outdoor Model
BM36UYC BMHH24Y21C
Power supply V,Hz,Ph 208/230V,1Ph,60Hz 208/230V,1Ph,60Hz
Cooling
Capacity Btu/h 36000 24000
Input W 4000 1920
Rated current W 18.3 8.52
EER Btu/W 9.0 12.5
SEER 16.5 20.5
Heating at 47F
Capacity Btu/h 40000 24000
Input W 3478 1846
Rated current W 15.9 8.19
COP W/W 3.37 3.81
HSPF4 11.5 12.5
HSPF5 10 10.6
Heating at 17F Capacity Btu/h 27600 17200
Minimum circuit ampacity A 30 20
Max.fuse A 50 30
Indoor fan motor
Model ZKFN-300-8-1 ZKFN-160-8-1-2
Qty 1 1
Input W 250.0) 90.0
RLA A 1.6 1.5
Speed r/min 1130/1050/990 880/820/690
Indoor air flow (Hi/Med/Lo) (No duct) m3/h 1840/1550/1195 1320/1180/740
Indoor air flow (Hi/Med/Lo) (No duct) CFM 1082/912/703 776/694/435
ESP
Range Pa 0-160 0-160
Range In. wg. 0-0.64 0-0.64
Indoor noise level (Hi/Med/Lo) dB(A) 45.5/42/39 44/41/38
Indoor unit
Dimension
(WxDxH)
mm 1360x774x249 1100x774x249
inch 54x30x10 43x30x10
Packing(WxDxH)
mm 1570x805x305 1305x805x305
inch 62x32x12 51x32x12
Net/Gross weight
kg 48.3/55.5 39.4/46.7
lbs. 106/122 87/103
Design pressure PSIG 550/340 PSIG 550/340 PSIG
Drainage water pipe diameter mm ODΦ25 ODΦ25
Refrigerant piping
Liquid side/ Gas
side
mm
Φ9.52/Φ15.9(3/8"/5/8")
Φ9.52/Φ15.9(3/8"/5/8")
Controller Wired control Wired control
Room temperature
Cooling
1732 1732
6290 6290
Heating
030 030
3286 3286
Operation temperature
17~30 17~30
62~86 62~86
Application area (cooling standard) m2 48-70.3 32-47
Application area (cooling standard) sq.ft 517-757 344-505
Qty’per 20’ /40’ /40'HQ Indoor unit 49/105/120 77/161/184