Ceiling Cassette Air Handler Installation Manual

CAUTION
All eld wiring and components must be installed by a licensed electrician and must comply with
relevant European and national regulations.
Use copper wire only.
Follow the 'Wiring diagram' attached to the unit body to wire the outdoor unit, indoor units and
the remote controller.
A circuit breaker capable of shutting down power supply to the entire system must be installed.
Note that the operation will restart automatically if the main power supply is turned o and then
turned back on again.
Be sure to ground the air conditioner.
DO NOT connect the ground wire to gas pipes, water pipes, lightning rods, or telephone ground
wires.
Gas pipes: might cause explosions or re if gas leaks.
Water pipes: no grounding eect if hard vinyl piping is used.
Telephone ground wires or lightning rods: might cause abnormally high electric potential in the
ground during lightning storms.
7
Electrical Wiring
How to connect wiring
Remove the control box lid of the
indoor unit.
Remove the cover of the outdoor unit.
Follow the "Wiring diagram label"
attached to the indoor unit's control
box lid to wire the outdoor unit, indoor
unit and the remote control. Securely
x the wires with a eld supplied
champ.
Attach the cover of the outdoor unit.
1
2
4
5
6
3
7
1 Control box lid
2 Wiring diagram label
3 Power supply terminal block
4 Clamp for wiring
5 Wiring between units
6 Plastic cover
7 Clamp (field supply)
Fig 7.1
Power
Model Phase Frequency
and volt
Circuit breaker/
Fuse(A)
12K~18K 1Phase 208-240V 20/16
Page 16
Revised 5/14/2020
Electrical
Wiring