Concealed Ducted Air Handler Installation Manual

10
Wiring
NOTE: This diagram is for explanation purposes
only. Your machine may be slightly dierent.
Wiring
Page 26
Revised 5/14/2020
1. All wiring must comply with local and national electrical codes, regulations and must be
installed by a licensed electrician.
2. All electrical connections must be made according to the Electrical Connection Diagram
located on the panels of the indoor and outdoor units.
3. If there is a serious safety issue with the power supply, stop work immediately. Explain
your reasoning to the client, and refuse to install the unit until the safety issue is properly
resolved.
4. Power voltage should be within 90-110% of rated voltage. Insucient power supply can
cause malfunction, electrical shock, or re.
5. Power from your panel must be on a dedicated circuit with the correct amperage breaker,
run through an approved electrical disconnect box mounted on an exterior wall near the
condenser.
6. Make sure to properly ground the air
conditioner.
7. Every wire must be rmly connected.
Loose wiring can cause the terminal
to overheat, resulting in product
malfunction and possible re.
8. Do not let wires touch or rest against
refrigerant tubing, the compressor, or
any moving parts within the unit.
9. If the unit has an auxiliary electric heater,
it must be installed at least 40" away
from any combustible materials.
10. To avoid getting an electric shock, never
touch the electrical components soon after
the power supply has been turned o.
11. Make sure that you do not cross
your electrical wiring with your signal
wiring. This may cause distortion and
interference.
BEFORE PERFORMING ANY ELECTRICAL WORK, READ THESE REGULATIONS
Indoor unit
Outdoor unit
(purchased seperately)
Disconnect switch
(purchased seperately)
Outdoor unit power wires
Indoor & Outdoor
connective wires
WARNING
BEFORE PERFORMING ANY ELECTRICAL OR
WIRING WORK, TURN OFF THE MAIN POWER
TO THE SYSTEM.