Copper Line Presentation
The copper lines should be run along the wall and as hidden as possible.
Minimum semi diameter of bending the pipe is 4 inches.
If the outdoor unit is higher than the
wall piping hole, a U-Shaped curve
should be bent into the copper lines
before the pipe goes into the wall. This
prevents moisture from running down
the lines and into the conditioned
space.
Lineset covers are sold as the optimal
accessory, which cover the copper lines,
drain tubing, and multiconductor wire.
These sets are fully customizable, and
in most cases, can be painted to match
the exterior of the home.
If installing a single zone Blueridge Minisplit, please skip to
Leak Detection to continue installation on PAGE 27 .
The next section is for Blueridge Multizone customers.
Drain Pipe
Outdoor Unit
Copper Line Sets
(ends must be flared)
Pipe Joints on Outdoor Unit
(under handle)
Wall
Indoor Unit
Img 9 | Connecting Copper Lines
Installation of a Single Zone Outdoor Unit