Connecting the Multiconductor Wire
• Open the front panel of the indoor air handler, remove the screw on the
wiring cover, and remove the cover.
• Feed the multi conductor control/power wire through the access port on
the back of the unit and pull it through from the front side as shown in
Image 4a.
• Remove the wire clip and connect the wires to each terminal. Please note
that the associating wires MUST match the terminals of the outdoor unit.
Color coded multiconductor is highly recommended as seen in Img 4b.
• Put the wiring cover back in place and tighten the screw.
• Close the front panel of the indoor air handler.
7
Installation of the Indoor Air Handler
Hex Nut Diameter (in) Tightening Torque (ft-lbs)
1/4 10-13
3/8 25-30
1/2 36-45
5/8 50-60
• If the lines are not already insulated, wrap them with insulation and tape
the insulation in place.