Owner's Manual Original Instructions Split Air Conditioner CONTENTS Safety precautions ...................................................................................... 01 Parts name .................................................................................................. 05 Operation and introduction of remote controller ............................................ 06 Clean and maintenance ...............................................................................
BMKH09M-LM BMKH12M-LM BMKH18M-LM BMKH24M-LM
Explanation of Symbols WARNING This symbol indicates the possibility of death or serious injury. CAUTION This symbol indicates the possibility of injury or damage to property. NOTICE Indicates important but not hazard-related information, used to indicate risk of property damage. Exception Clauses Manufacturer will bear no responsibilities when personal injury or property loss is caused by the following reasons. 1.Damage the product due to improper use or misuse of the product; 2.
FCC WARNING WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC STATEMENT This device complies with Part 15 of the FCC Rules.Operation is subject to the following two conditions : (1) this device may not cause harmful interference, and (2) this device must accept any interference received,including interference that may cause undesired operation.
IC STATEMENT This equipment complies with FCC’s and IC’s RF radiation exposure limits set forth for an uncontrolled environment. The antenna(s) used for this transmitter must be installed and operated to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. Installers must ensure that 20cm separation distance will be maintained between the device (excluding its handset) and users.
Safety precautions WARNING Installation Installation or maintenance must be performed by qualified professionals. The appliance shall be installed in accordance with national wiring regulations. According to the local safety regulations, use qualified power supply circuit and circuit breaker. All wires of indoor unit and outdoor unit should be connected by a professional. Be sure to cut off the power supply before proceeding any work related to electricity and safety.
Safety precautions CAUTION Installation Instructions for installation and use of this product are provided by the manufacturer. Select a location which is out of reach for children and far away from animals or plants. If it is unavoidable, please add the fence for safety purpose. The indoor unit should be installed close to the wall. Don't use unqualified power cord. If the length of power connection wire is insufficient, please contact the supplier for a new one.
Safety precautions WARNING Operation and Maintenance This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Safety precautions CAUTION Operation and Maintenance Do not spill water on the remote controller, otherwise the remote controller may be broken. Do not use fire or hair dryer to dry the filter to avoid deformation or fire hazard. Do not block air outlet or air inlet. It may cause malfunction. Do not step on top panel of outdoor unit, or put heavy objects. It may cause damage or personal injury.
Parts name Indoor Unit air inlet panel filter aux. button air outlet horizontal louver If remote controller is lost or damaged, please use aux. button to turn on or turn off the air conditioner. The operation in details is as below: As shown in the figure, open panel and press aux. button to turn off the air conditioner. When the air conditioner is turned on, it will operate under auto mode. Display Temp.
Operation and introduction of remote controller Introduction for icons on display screen Buttons on remote controller I feel Operation mode Set fan speed MODE FAN SWING TURBO SLEEP TEMP Turbo mode Send signal Auto mode Cool mode Dry mode Fan mode Heat mode Sleep mode 8℃ heating function Health mode Scavenging function X-FAN function Set temp. Temp. display type WiFi LIGHT CLOCK TIMER TIMER ON OFF Indoor ambient temp. Outdoor ambient temp.
Introduction for buttons on remote controller ● When selecting dry mode, the air conditioner operates at low speed under dry mode. Under dry mode, fan speed can't be adjusted. Press "SWING" button to adjust fan blowing angle. ● When selecting fan mode, the air conditioner will only blow fan, no cooling and no heating. Press "FAN" button to adjust fan speed. Press "SWING" button to adjust fan blowing angle. ● When selecting heat mode, the air conditioner operates under heat mode.
change quickly. On releasing button after setting is finished, temperature indicator on indoor unit will change accordingly. (Temperature can't be adjusted under auto mode) When setting TIMER ON, TIMER OFF or CLOCK, press "▲" or "▼" button to adjust time. (Refer to CLOCK, TIMER ON, TIMER OFF buttons) ● Having set X-FAN function on: After turning off the unit by pressing " " button, indoor fan will continue running for a few minutes at low speed.
WiFi decrease 1min. Holding "▲" or "▼" button, 2s later, the time will change quickly until reaching your required time. Press "TIMER ON" to confirm it. The word "ON" will stop blinking. " " icon resumes displaying. Cancel TIMER ON: Under the condition that TIMER ON is started up, press "TIMER ON" button to cancel it. ● TIMER OFF button "TIMER OFF" button can set the time for timer off. After pressing this button, " " icon disappears and the word "OFF" on remote controller blinks.
NOTE I FEEL Function ● Under energy-saving function, fan speed is defaulted at auto speed and it can't be adjusted. Press "▲" and "MODE" buttons simultaneously to start I FEEL function and " " will be displayed on the remote controller. After this function is set, the remote controller will send the detected ambient temperature to the controller and the unit will automatically adjust the indoor temperature according to the detected temperature.
Clean and maintenance WARNING ■ The filter should be cleaned every three months. If there is much dust in the operation environment, clean frequency can be increased. ■ After removing the filter, do not touch fins to avoid injury. ■ Do not use fire or hair dryer to dry the filter to avoid deformation or fire hazard. WARNING ■ Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock.
Checked items before maintenance Phenomenon General phenomenon analysis Please check below items before asking for maintenance. If the malfunction still can’t be eliminated, please contact local dealer or qualified professionals. Phenomenon Check items Whether it's interfered severely (such as static electricity, stable voltage?) No air emitted from indoor unit Whether there are obstacles? Pull out the plug. Reinsert the plug after about 3min, and then turn on the unit again. Remove obstacles.
Installation notice WARNING sure that the unit is running in cooling mode. Then, fully close the valve at high pressure side (liquid valve). About 30-40 seconds later, fully close the valve at low pressure side (gas valve), immediately stop the unit and disconnect power. Please note that the time for refrigerant recovery should not exceed 1 minute. If refrigerant recovery takes too much time, air may be sucked in and cause pressure rise or compressor rupture, resulting in injury.
Requirements for electric connection Selection of installation location Basic requirement 7.If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard . 8.The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube. 9.The appliance shall be installed in accordance with national wiring regulations.
Installation of indoor unit NOTE Step 1: Choose installation location outdoor Φ55 Φ70 5-10 Recommend the installation location to the client and then confirm it with the client. Step 2: Step 4: Install wall-mounting frame Outlet pipe 1.Hang the wall-mounting frame on the wall; adjust it in horizontal position with the level meter and then point out the screw fixing holes on the wall. 1. The pipe can be led out in the direction of right, rear right, left or rear left. 2.
Hex nut diameter Tightening torque (N.m) 1/4'' 15~20 3/8'' 30~40 1/2'' 45~55 5/8'' 60~65 3/4'' 70~75 drain hose insulating pipe NOTE ● Add insulating pipe in the indoor drain hose in order to prevent condensation. ● The plastic expansion particles are not provided. 4. Wrap the indoor pipe and joint of connection pipe with insulating pipe, and then wrap it with tape. Step 7: Connect wire of indoor unit NOTICE ● All wires of indoor unit and outdoor unit should be connected by a professional.
drain hose connection pipe 3. Remove the wire clip; connect the power connection wire to the wiring terminal according to the color; tighten the screw and then fix the power connection wire with wire clip. band indoor power cord N(1) 2 3. Bind them evenly. 4. The liquid pipe and gas pipe should be bound separately at the end. 3 white black red green (blue) (brown) (yellowgreen) NOTICE ● The power cord and control wire can't be crossed or winding. ● The drain hose should be bound at the bottom.
Test and operation Check after installation ● Check according to the following requirement after finishing installation. Items to be checked Has the unit been installed firmly? Have you done the refrigerant leakage test? Possible malfunction The unit may drop, shake or emit noise. It may cause insufficient cooling(heating) capacity. Is heat insulation of pipe- It may cause condensation and water dripping. line sufficient? Is water drained well? It may cause condensation and water dripping.
Configuration of connection pipe 48000Btu/h (14064W) 30 350 120 120 50 20 250 350 30 _ 42000Btu/h (12306W) 7/8'' 30 250 36000Btu/h (10548W) _ 30 3/4'' 28000Btu/h (8204W) 60 25 1'' or 1 1/4'' 24000Btu/h (7032W) 5/8'' 25 30 18000Btu/h (5274W) 3/4'' or 7/8'' 20 1/2'' 12000Btu/h (3516W) 15 15 5/8'' or 3/4'' 9000Btu/h (2637W) 1/4'' or 3/8'' 15 15 7000Btu/h (2051W) 3/8'' or 1/2'' 15 1/4'' 5000Btu/h (1465W) Cooling only(g/m) Max.
B: Remove the burrs smooth surface ● Remove the burrs with shaper and prevent the burrs from getting into the pipe. improper expanding pipe shaper downwards the length is equal leaning damaged crack surface uneven thickness Working temperature range Indoor side Outdoor side DB/WB(°C/°F) DB/WB(°C/°F) C: Put on suitable insulating pipe Maximum cooling D: Put on the union nut ● Remove the union nut on the indoor connection pipe and outdoor valve; union pipe install the union nut on the pipe.
66129936930